Microcom 466 User Manual
Page 45
![background image](https://www.manualsdir.com/files/798526/content/doc045.png)
Chapter 5
Printer Commands
466 Operators Manual
39
^A
^D
COMMAND
24
Change SW4: Change software switch bank #4.
12345678
^ABxxxxxxxx
*******.)))))),
******.)))))),*
*****.)))))),**
****.)))))),***
**** 0000 = Not decoded (8 bit)
**** 0001 = Danish (7 bit)
**** 0010 = 860 (8 bit)
**** 0011 = Spanish (7 bit)
**** 0100 = 850 (8 bit)
**** 0101 = German (7 bit)
**** 0110 = 865 (8 bit)
**** 0111 = Swiss (7 bit)
**** 1000 = 852 (8 bit)
**** 1001 = French (7 bit)
**** 1010 = 863 (8 bit)
**** 1011 = Swedish (7 bit)
**** 1100 = 437 (8 bit)
**** 1101 = Italian (7 bit)
**** 1110 = British (7 bit)
**** 1111 = US English (7 bit)
****
***.)))))) 1=Auto-size on Power-up, 0=Disable
**.))))))) 1=Blow-hole Sensing Enable, 0=Disable
*.)))))))) Always 0
.))))))))) 1=Enable Slashed Zeros, 0=Disable
Position:
1
Slashed Zeros: If enabled, the printer will print the zero character with a slash.
2
Always 0
3
Blow-hole Stock: Enable this position when using blow-hole or cut-slot stock:
Stock that uses a hole instead of a gap to separate labels.
4
Auto-size on power-up: When enabled, the printer automatically sizes the label
stock when turned on. The printer then uses these header values for all
subsequent label formats. See the ^D39 command in section 5.3 for more
information on auto-sizing.
5
Code Page Selection
6
Code Page Selection
7
Code Page Selection
8
Code Page Selection