beautypg.com

Microcom 322M User Manual

Page 55

background image

Chapter 6

Printer Commands

322M Operator’s Manual

51

printer to clear the increment/decrement function of text string number 1 or the
first text string.


^A

^D

COMMAND

XX

88

Load Field Number to Increment by 1: The ^Axx specifies which field to
increment by one.


XX

89

Load Field Number to Decrement by 1: The ^Axx specifies which text string
field that will be decremented by one.



A sample format using the single serial number function:

^D57

1,575,609,,25,35,0,1,285,0,0

1,280,300,2,1,5

^D56

^A2^D86

^A1^D84

^A5^D85

^A3^D75

^D2

20

^D3


This format would enable the decrement function (^A2^D86). Select text string #1 to
decrement (^A1^D84), load the step value of 5 (^A5^D85) and then print three serialized
labels (^A3^D75). The printed result would be “20” for the first label, “15” for the second
label,

and “10” for the third or last label.




A sample format using the multiple serial number function:

^D57

2,575,609,,25,35,0,1,285,0,0

1,280,300,3,1,5

2,280,100,3,1,5

^D56

^A1^D88

^A2^D89

^A3^D75

^D2

100

200

^D3


This format would enable the multiple serial number function and select the first text string to
increment by one (^A1^D88), the second field to decrement by one (^A2^D89), and print