Microcom 322M User Manual
Page 39
![background image](https://www.manualsdir.com/files/798519/content/doc039.png)
Chapter 5
Designing Labels Using LDS
322M Operator’s Manual
35
Bar Code Symbologies
SYMBOL
CGN
VALUE
RATIO
HEIGHT
SPACING
FO **
Code 39
2
3
5
8
2:1
3:1
5:2
8:3
1
1
1
1
2
2
2
3
0123
0123
0123
0123
I 2 of 5
2
3
5
2:1
3:1
5:2
1
1
1
-
-
-
0123
0123
0123
UPC / EAN *
-
40 %
1
-
0123
UPC Readable *
-
40 %
1
-
0123
Code 128 & UCC / EAN 128 *
-
40 %
1
-
0123
Codabar
2
3
5
2:1
3:1
5:2
1
1
1
-
-
-
0123
0123
0123
Code 93
-
2:1
1
-
0123
AS-10
-
2:1
1
-
0123
Maxicode (CGN = Mode)
2
3
4
5
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0123
0123
0123
0123
0123
MSI (Modified Plessey)
-
1:1
1
-
0123
Table 11
CGN
– Bar Code Symbologies
* These Symbologies must use the CMX or CMY multipliers by 2 to produce a 80% ratio.
** The “FO” field represents the available Field Orientation or print rotation. See section
5.6.7.