Chapter 4: communication, 1 rs-232d serial – Microcom 322M User Manual
Page 25
![background image](https://www.manualsdir.com/files/798519/content/doc025.png)
322M Operator’s Manual
21
Chapter 4: Communication
4.1
RS-232D Serial
The printer provides a 9 pin female D-Sub connector, on the rear panel, for RS-232D serial
communication. The printer is configured as DCE (Data Circuit-terminating Equipment) so a
NULL modem cable is not necessary. A serial data cable is required to use serial
communications, refer to Table 7 below for correct cable configurations.
The factory settings, unless otherwise requested, are set at 9600 baud, 8 data bits, 1 stop
bit and no parity with both hardware and software handshaking enabled. The baud rate is
user selectable from 1200 to 115,200 and uses software XON/XOFF flow control and/or
hardware CTS handshaking.
9 to 9 Pin Cable
9 to 25 Pin Cable
State
322M
DE-9
Pin #
Signals /
Direction
PC
DE-9
Pin #
State
322M
DE-9
Pin #
Signals /
Directions
PC
DB-25
Pin #
XX
1
DCD
DCD
1
HI
1
DCD
DCD
8
XX
2
TXD
RXD
2
XX
2
TXD
RXD
3
XX
3
RXD
TXD
3
XX
3
RXD
TXD
2
HI
4
DTR
DSR
4
HI
4
DTR
DSR
20
LO
5
GND
GND
5
LO
5
GND
GND
7
HI
6
DSR
DTR
6
HI
6
DSR
DTR
6
DC
7
RTS
CTS
7
DC
7
RTS
CTS
4
XX
8
CTS
RTS
8
XX
8
CTS
RTS
5
HI
9
+5V
+5V
9
HI
9
+5V
-
DC = DO NOT CARE
XX = INDETERMINATE
Table 7
RS-232 Cable Configurations
If XON/XOFF handshaking is used, the only signals that the printer requires are the RXD,
TXD, and GND signals. If the hardware handshaking is used the CTS and RTS signals are
required. The other signals are offered in the event that the host computer would require
them.