Chapter 5
Designing Labels Using LDS
322M Operator’s Manual
27
406 (2” X 203 = 406). There is a maximum of 575 dots in the X direction (width), while the Y
direction (height) is virtually unlimited with the standard print head. The auto-size command
(^A2^D39
different properties of the media being used. This provides a good starting point in
determining the proper values.
Below is a list of the header element mnemonics and their default values:
HFM, LSX, LSY, WEB, GAP, DPS, LCB, AGD, SPG, OFX, OFY
0, 832, 614, 13, 24, 35, 0, 1, 285, 0, 0
Figure 9
Header Elements
5.4.1
HFM
(Number of Fields in Layout)
This parameter is used to specify the number of fields in the layout. If more format fields are
defined than specified in the HFM parameter, they will be ignored and will not print. The
HFM was set to a value of 5 in the format used to create the sample in Figure 8. This
means that a total of five format fields are to be generated. If the HFM was changed to 4,
only the first four format fields would be generated.
Label
LSX (Always 575)
Die-cut label
backing
This is the
origin; 1, 1
M i c r o c o m
C o r p o r a t i o n
Thermal Printing Solutions
012345
WEB
GAP
LSY
PRINT DIRECTION