Microcom 226 Users Guide User Manual
Page 37

Chapter 4
Printer Modes
226/426 User’s Guide
27
Figure 10
^D326-List Settings Example
Figure 11
^D325-List Selections Example
Settings (D326 or
Operational
Print Speed:
(D635) 6.0 ips
Detector mode:
(D636) 0 (none)
Slew Speed:
(D645) 6.0 ips
Darkness:
(D690) 75 (Dark)
Retraction delay:
(D641) 0.5 sec.
Print delay:
(D640) 0.0 sec.
Labels printed:
(D655) 42
Distances
Label width (LSX):
(D631) 3.34 inches
Label height (LSY):
(D632) 1.5.12 inches
Reg. mark height (GAP):
(D633) 0.148 inches
To reg’n mark (DRM):
(D634) 0.0 inches
X offset (OFX):
(D637) 0.0 inches
Y offset (OFY):
(D638) 0.0 inches
Dist. Past Gap (DPG):
(Auto)
1.225 inches
Activate Gap Det (AGD)
(Auto)
0.0 inches
Advance/retract:
(D642) 0.512 inches
Serial port settings
(D670) 9600,N,8,1
Ethernet
Active at 10/100
MAC:
0x000257795634
Printer IP:
(D675) 192.168.200.3
Server/Host IP:
(D675) 192.168.200.1
Gateway IP:
(D675) 192.168.200.1
Broadcast Mask:
(D675) 192.168.200.255
Net Mask:
(D675) 255.255.255.0
USB port settings
Not installed
Thresholds
Gap:
29
Black line:
98
Stock:
110
High head temperature:
147
Low head temperature:
24
PWM periods
Gap:
64
Black line:
41
Label Present:
64
Stacker:
64
NOTE: Some items may not be correct until after a scripted
label is printed or Auto-size (D310) is run.
Selections (D325 or
Operational
Dispense mode:
(D597) 3
Emulation:
(D501) Microcom 426
Cutter Type:
(D506) NONE
PMH Type:
(D507) NONE
Button Mode:
(D541) 1
Response Mode:
(D550) verbose
Automatic responses:
(D580) Errors
Power-up label:
(D586) 1
Detector mode:
(D636) 0 (none)
General
Measurement units:
(D564) 1 (inches)
Speed units:
(D565) 1 (ips)
Temperature units:
(565)
1 (Fahrenheit)