Cli notification alarm events – Meinberg SHSPZF LANTIME User Manual
Page 85
![background image](https://www.manualsdir.com/files/798020/content/doc085.png)
CLI Notification
Alarm events
On this page you can set up different notification types for a number of events. This
is an important feature because of the nature of a timeserver: running in the
background. If an error or problem occurs, the timeserver is able to notify an
administrator by using a number of different notification types.
The LANTIME timeserver offers four different ways of informing the administrator
or a responsible person about nine different events: EMAIL send an e-mail message
to a specified e-mail account, SNMP-TRAP sends a SNMP trap to one or two SNMP
trap receivers, WINDOWS POPUP MESSAGE sends a Winpopup message to one or
two different computers and DISPLAY shows the alarm message on a wall mount
display model VP100/NET, that is an optional accessory you can obtain from us.
Here is a table of all events:
"NTP not sync"
NTP is not synchronised to a reference time source
"NTP stopped"
NTP has been stopped (mostly when very large time offsets
occur)
"Server boot"
System has been restarted
"Receiver not responding"
No contact to the internal GPS receiver
"Receiver not sync"
Internal GPS clock is not synchronised to GPS time
"Antenna faulty"
GPS antenna disconnected
"Antenna reconnect"
GPS antenna reconnected
"Config changed"
Configuration was changed by a user
„Leap second announced“
A leap second has been announced
“TIME LIMIT ERROR”
SHS detected time difference
85