SNMP branch

Variable

Data type

Description

mbgLtCfgNtpServer3KEY

integer

Link to the key which should be used

for the third NTP-server

mbgLtCfgStratumLocalClock

integer(0..15)

Stratum-value of the internal system

clock of the timeserver

mbgLtCfgNTPTrustedKey

integer

Link to the key which should be used

for the internal reference time source

mbgLtCfgNTPBroadcastIP

string (IPv4 or IPv6-

address)

IP-address, which has to be used for

NTP-broadcasts (or multicasts)

mbgLtCfgNTPBroadcastKey

integer

Link to the key which should be used

for outgoing NTP-broadcasts

mbgLtCfgNTPBroadcastAutokey

integer (0 =

disabled, 1 =

enabled)

Use autokey for NTP broadcasts?

mbgLtCfgAutokeyFeature

integer (0 =

disabled, 1 =

enabled)

Use autokey feature of the NTP server?

mbgLtCfgAtomPPS

integer (0 =

disabled, 1 =

enabled)

Atom PPS (pulse per second) activated?

mbgLtCfgEMail

mbgLtCfgEMailTo

string (Liste von

EMail-addressn)

One or more (semicolon separated)

email address(es). which should receive

warnings and alarm notifications from

the timeserver

mbgLtCfgEMailFrom

string (EMail-

address)

The EMail-address which is used as the

senders address for email notifcations

mbgLtCfgEMailSmarthost

string (IPv4 or IPv6-

address or

hostname)

The SMTP-host, which is used for

sending mails

mbgLtCfgSNMP

mbgLtCfgSNMPTrapReceiver1

string (IPv4 or IPv6-

address or

hostname)

First host, which receives notifications

sent as SMTP-traps

mbgLtCfgSNMPTrapReceiver1Commu

nity

string

The SNMP community used when

sending SNMP-Traps to the first host

mbgLtCfgSNMPTrapReceiver2

string (IPv4 or IPv6-

address or

hostname)

Second host, which receives

notifications sent as SMTP-traps

mbgLtCfgSNMPTrapReceiver2Commu

nity

string

The SNMP community used when

sending SNMP-Traps to the second host

mbgLtCfgSNMPROCommunity

string

The SNMP community, which has read-

only access and therefore can be used to

only monitor status variables or

configuration values (SNMP V2c)

mbgLtCfgSNMPRWCommunity

string

The SNMP community, which has read-

write access and there for can be used to

monitor status variables and get/set

configuration values (SNMP V2c)

mbgLtCfgSNMPContact

string

Contact information (e.g. name of a

contact person) of the timeserver

mbgLtCfgSNMPLocation

string

Location (e.g. building/room number) of

the timeserver

mbgLtCfgWinpopup

mbgLtCfgWMailAddress1

string

First receiver of notifications sent as

windows popup messages

mbgLtCfgWMailAddress2

string

Second receiver of notifications sent as

windows popup messages

mbgLtCfgWalldisplay mbgLtCfgVP100Display1IP

string (IPv4 or IPv6-

address or

hostname)

hostname or IP-address of the first

wallmount display used for showing

notifications

mbgLtCfgVP100Display1SN

string (Hexstring)

The serial number of the first wall

mount display used for showing

notifications (can be found in the setup

menu of the display)

mbgLtCfgVP100Display2IP

string (IPv4 or IPv6-

address or

hostname)

hostname or IP-address of the second

wall mount display used for showing

notifications

mbgLtCfgVP100Display2SN

string (Hexstring)

The serial number of the first wall

mount display used for showing

notifications (can be found in the setup

menu of the display)