The watchdog timer period is set via a jumper. The default position of 30 seconds is shown above. Table 6-1
below describes the W/D timer settings as well as the other header pins.

Table 6-1. Watch Dog Timer Settings

Pin

Description

1

30 S timeout when jumpered to Pin2

2

See above

3

10 second timeout when jumpered to Pin 4

4

See above

5

1 second timeout when jumpered to pin 6

6

See above

7

Alarm_Out/n (TTL)

8

PC +5V

9

Alarm_Out (open collector up to +12V)

10

Alarm _Out 5K pullup TO 5V when jumpered to
pin 9

11

SPDT Relay Common

12

SPDT Relay Normally Open

13

No Connection

14

SPDT Relay Normally Closed

15

No Connection

16

No Connection

6.4

EXAMPLE PROGRAMS

Example programs written in C/C++, Visual Basic (v5.0 and later), and Delphi (v3.0 and later) are included with
the Satellite Monitor. They demonstrate how to use each of the API functions provided by the Satellite Library.