WEB-TC User's Guide

Signal I/O Connections

18

WEB-TC screw terminal descriptions

Pin Signal Name

Pin Description

Pin

Signal Name

Pin Description

1

RSVD*

Reserved

27

RSVD*

Reserved

2

NC*

No connect

28

AGND

Analog ground

3

C0H

CH0 sensor input (+)

29

C7L

CH7 sensor input (-)

4

C0L

CH0 sensor input (-)

30

C7H

CH7 sensor input (+)

5

RSVD*

Reserved

31

RSVD*

Reserved

6

RSVD*

Reserved

32

RSVD*

Reserved

7

C1H

CH1 sensor input (+)

33

C6L

CH6 sensor input (-)

8

C1L

CH1 sensor input (-)

34

C6H

CH6 sensor input (+)

9

AGND

Analog ground

35

NC*

No connect

10

RSVD*

Reserved

36

RSVD*

Reserved

11

RSVD*

Reserved

37

RSVD*

Reserved

12

NC*

"No Connect"

38

AGND

Analog ground

13

C2H

CH2 sensor input (+)

39

C5L

CH5 sensor input (-)

14

C2L

CH2 sensor input (-)

40

C5H

CH5 sensor input (+)

15

RSVD*

Reserved

41

RSVD*

Reserved

16

RSVD*

Reserved

42

RSVD*

Reserved

17

C3H

CH3 sensor input (+)

43

C4L

CH4 sensor input (-)

18

C3L

CH3 sensor input (-)

44

C4H

CH4 sensor input (+)

19

AGND

Analog ground

45

NC*

No connect

20

RSVD*

Reserved

46

RSVD*

Reserved

21

+5V

+5V output

47

NC*

No connect

22

PU/D

Pull-up/down for digital outputs

48

GND

Digital ground

23

DIO0

Digital Input/Output

49

DIO7

Digital Input/Output

24

DIO1

Digital Input/Output

50

DIO6

Digital Input/Output

25

DIO2

Digital Input/Output

51

DIO5

Digital Input/Output

26

DIO3

Digital Input/Output

52

DIO4

Digital Input/Output

*Make no connection to terminals labeled

NC

or

RSVD

.

Use 16 AWG to 30 AWG wire for your signal connections.

Tighten screw terminal connections

When making connections to the screw terminals, be sure to tighten the screw until tight. Simply touching the
top of the screw terminal is not sufficient to make a proper connection.

Thermocouple input terminals (C0H/C0L to C7H/C7L)

You can connect up to eight thermocouples to the differential sensor inputs (C0H/C0L to C7H/C7L).

The WEB-TC supports type J, K, R, S, T, N, E, and B thermocouples. The thermocouple type you select will
depend on your application needs. Review the temperature ranges and accuracies of each type to determine
which is best suited for your application. You can connect a different thermocouple type to each channel.

CJC sensors

The WEB-TC has four built in high-resolution temperature sensors for thermocouple measurements. Each CJC
sensor is dedicated to two thermocouple input channels, and is located behind the associated channel's screw
terminal. These sensors measure the ambient temperature at the terminal block so that the cold junction voltage
can be calculated.

Digital terminals (DIO0 to DIO7)

You can connect up to eight digital I/O lines to the screw terminals labeled

DIO0

to

DIO7

. Each terminal is

software configurable for input or output. A

PU/D

terminal is provided for pull-up/down configuration

(explained on page 19).

If a digital bit is set up as an alarm, the bit is configured for output and assumes the state defined by the alarm
configuration.