beautypg.com

MEGA Corp. MMP4-2 User Manual

Page 45

background image

MMP 4-2
5 Nov 2011

SECTION 8

Scheduled Inspections

8-4


FREQUENCY

STEP

HYDRAULIC SYSTEM

DAILY

250

Hours

500

Hours

1000

Hours

1

Check hydraulic oil for proper
level, clarity, foaming and signs of
contamination.
Repair, adjust or replace as
required.

X

2

Check hydraulic control valve for
security, damage, function and
leaks.
Repair as required.

X

3

Check hydraulic pump for
security, damage and leaks.
Repair as required.

X

4

Check hydraulic oil cooler for
security, damage and leaks.
Repair as required.

X

5

Check

hydraulic

hosing

for

security, damage and leaks.
Repair as required.

X

6

Check hydraulic cylinders and flow
controls for security, damage and
leaks.
Repair as required.

X

7

Check hydraulic oil filter for
security, damage and leaks.
Repair as required

X

8

Check

hydraulic

pressure

regulator for function and pressure
setting (2,100 psi or 14,450 kpa).
Adjust or repair as required.

X

9

Drain and refill hydraulic reservoir
and

replace

hydraulic

filter

element.

X

10

Check

hydraulic

pump

drive

coupling for wear, security and
damage.
Repair as required.

X