5 Nov 2011

SECTION 5

Water Pump Assembly

5-9

6. Use anti-seize compound on all threaded

fasteners when re-assembling pump.



DO NOT USE ANTI-SEIZE ON SEALS
OR BEARINGS. If an anti-seize
compound is used in this application
bearing and/or seal failure will result.

7. Ensure pressure and return pipes are

connected to proper ports on the hydraulic
motor.









8. Install strainer to pump inlet, tightening (4)

retaining bolts (Item 14).

9. Inspect mounting gasket for damage,

replace as necessary.

10. Install pump assembly to suction pipe,

tighten fasteners.

11. Hook up hydraulic hoses.

12. Check hydraulic fluid level, adjust level as

required.

13. Check to ensure hydraulic pump inlet valve

is OPEN.

14. Run unit, engage water pump control,

ensure proper rotation of water pump and
no leaks are present.



Motor rotation is counter-clockwise looking
from discharge end of pump.










15. Shut unit off and recheck hydraulic fluid

level, at 80% to 90% of the level shown in
the sight glass, adjust level as required.


RETURN

PRESSURE