beautypg.com

Kemppi Protig 501L User Manual

Page 28

background image

28 – PROMIG 501, PROMIG 511/0537

© KEMPPI OY

5. PROMIG 501, 511

A001 JUMPER BLOCK FUNCTIONS

1. Selection of wire feeder address

Feeder 1, address 102

Feeder 2, address 105

Feeder 3, address 150

Feeder 4, address 153

3. Welding with PROCOOL an air cooled MIG gun

COOLER is on, air/water cooling selection is air –> welding stops after 1 s

welding, Err 7 on display, on delivery

COOLER is on, air/water cooling selection is air –> welding is allowed (use

e.g. with TIG/MIG sets)

4. Linearize output, wfs and voltage, as a function of control voltage

Output is linear according to potentiometer turning angle, on delivery

Output is linear according to control voltage:
wfs: 0-5 V –>0-18,25 m/min, U2: 0-5 V –> 0-50 V

5. Disable PMT or WS MIG guns

PMT, WS and RMT10 functions enabled

PMT, WS and RMT10 functions disabler (Err11), only normal guns pos-

sible to use

Feeder address
Wfs speed