beautypg.com

Weld data / gas test, Selecto operations, mc panel – Kemppi Protig 501L User Manual

Page 19

background image

PROMIG 501, PROMIG 511/0537 – 19

© KEMPPI OY

Note! Display shows terminal voltage of power source. Depending on length and copper cross-

section of welding cables as well as on that of MIG guns real arc voltage and display might

differ many volts from each other, see table below.

Cable

50 mm

2

70 mm

2

95 mm

2

Voltage loss / 10 m

0,35 V / 100 A

0,25 V / 100 A

0,18 V / 100 A

When you adjust welding dynamics, display shows adjustment value for welding dynamics

-9...0...9 and value is kept on display still for approx. 3 s after end of adjustment. After that

display returns to show voltage.

3.1.1. WELD DATA / GAS TEST

Retrieval of welding parameters to displays,

Use of WELD DATA switch retrieves to displays those welding parameters, wire

feed speed, welding current, welding voltage which were used when welding was

stopped last. Welding values are indicated in display for so long as you are using

the WELD DATA switch and are kept in memory until you press again the start

switch for gun.

Testing the gas flow

A short press on the switch starts the flow of the shielding gas. The shielding gas flows for

approximately 20 seconds, or until the switch is pressed again.

3.1.2. SELECTO operations, MC panel

SELECTO is the name for the operation in which you can store welding parameters for memory

channels for reutilization. You can store to memory five sets of MIG/MAG welding values.

Parameters which can be stored are wire feed speed, welding voltage and welding dynamics.

Stored values are kept in memory though power is switched off from unit.
Note! You cannot store MMA welding values and MIG 2-sequence/4-sequence selection.

In SELECTO operations are three different operating modes:

SELECTO OFF:

Normal MIG/MAG welding with independent adjustments for wire feed speed and voltage,

SELECTO functions are not in use.
SELECTO ON:

Welding with stored welding values, wire feed speed, welding voltage and welding dynamics.

Only channel selection, channels 1...5 from panel is operating. Channel is selected, depending

on position of control mode, either with CH switch on panel, remote control unit or with regula-

ting module RMT 10 of PMT or WS gun. You can change the channel also during welding.
Digital displays indicate values for wire feed speed and voltage which are stored on the channel

in question. Stored value for welding dynamics can be brought to display by turning a little the

adjustment potentiometer for welding dynamics.
SELECTO SET:

Search of welding data for storage. Welding data are stored for wished channel by using the

SAVE switch. Those values for wire feed speed, voltage and welding dynamics are stored,

which were set before using the SAVE switch.

This manual is related to the following products: