Kemppi Protig 501L User Manual
Page 27
PROMIG 501, PROMIG 511/0537 – 27
© KEMPPI OY
R61
R63
R20
R10, RMT10
R61
4. OPERATIONS OF REMOTE CONTROL UNITS
IN PROMIG 501 AND 511 WIRE FEED UNITS
R63
R61
MIG
Setting for wire feed:
Setting for voltage:
I 1...18 m/min
10 V...max. voltage of power source
II 1...25 m/min
(35...46 V)
SELECTO
Channel selection: 1...5 corresponding
Fine adjustment for arc length:
to settings 1, 4, 6, 8, 10 of knob
1...10
SYNERGIC MIG Setting for power (wire feed speed):
Fine adjustment for arc length:
according to wire min. ... max.
1...10
SYNERGIC
Setting for power (wire feed speed):
PULSED MIG
according to wire min. ... max.
Fine adjustment for arc length: 1...10
MMA
Setting for power:
NO OPERATION
10 A ... max. power of power source
R61
MIG
Setting for wire feed:
I 1...18 m/min
II 1...25 m/min
SELECTO
Channel selection: 1...5 corresponds in the R10 settings
1, 4, 6, 8, 10 of knob
SYNERGIC MIG Setting for power (wire feed speed): according to wire min. ... max.
SYNERGIC
Setting for power (wire feed speed):
PULSED MIG
according to wire min. ... max.
MMA
Setting for power:
NOTE ! RMT10
10 A...max.power of power source