Ivoclar Vivadent IPS e.max Abutment Solutions Cem Kit User Manual
Page 9
9
The base is screwed on the model analog. The relative position to the
ceramic structure is marked with a waterproof pen.
Optional: The bonding surface can be carefully blasted according to the
instructions of the manufacturer.
Optional: Wax is applied in order to protect the emergence profile. In addi-
tion, the screw channel is sealed with wax.
Monobond Plus is applied to the clean bonding surface and allowed to react
for 60 s. After the reaction time, any remaining residue is dried with blown
air that is free of water and oil.
The screw channel is sealed with a foam pellet or wax. The bonding surface
must not be contaminated in the process.
– The emergence profile of the base must not be blasted or modified in any way!
– If the manufacturer recommends that the bonding surfaces be blasted, the following procedure should
be observed:
– Hard modelling wax is applied to protect the emergence profile, since this type of material is easy to remove
later on.
– The screw channel is also sealed with wax.
– The bonding area is carefully blasted according to the instructions of the manufacturer.
– An instrument and a steam cleaner are used for cleaning. It is important to remove all the wax meticulously.
– After the bonding surface has been cleaned, it must not be contaminated under any circumstances, as this would
impair the bond.
– Monobond Plus is applied on the clean bonding surface and allowed to react for 60 s. After the reaction time, any
residue is dispersed with air that is free of water and oil.
– The screw channel is sealed with a foam pellet or wax. The bonding surface must not be contaminated in the process.
If the manufacturer recommends that the bonding surfaces be
blasted, the following procedure should be observed:
Optional: Cleaning with an instrument and a steam cleaner. It is important
to remove all the wax meticulously.
emax AbutSol_Cem_GI_WE1_649681_REV1.indd 9