REPEATER/CROSS- REPEATER

28

Rev. : 09/25/2012

Appendix F: Specifications

Power

Voltage

90-240VAC-0.5A-47-63Hz/5VDC-2000 mA

Power required

Repeater/ Cross- Repeater Unit : max. 5V/750mA
operation mode CATx – Repeater:

ca. 500mA

operation mode Fiber Repeater

ca. 300mA

operation mode Cross Repeater

ca. 750mA

Interface

(Depending on type of device)

LC

Multimode or Singlemode – depending on device

RJ45

1000 MBit high speed transmission. Wiring according
to EIA/TIA 568B Gigabit Ethernet.

Maximum Length of Interconnection Cable (CATx)

CATx Installation cable AWG24

140m (400ft)

CATx Patchcable AWG26/8

70m (200ft)

Type of Interconnection Cable (CATx)

CATx Installation cable AWG24

S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or
Digital STP 17-03170. Four pairs AWG 24. Wiring
acc. EIA/TIA 568A (1000BaseT).

CATx Patchcable AWG26/7

S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or
Digital STP 17-03170. Four pairs AWG 26/7. Wiring
acc. EIA/TIA 568A (1000BaseT).