Repeater/cross- repeater, Catx / fiber cross- repeater – IHSE USA 471 Series Repeater/Cross- Repeater User Manual

Page 20

background image

REPEATER/CROSS- REPEATER

20

Rev. : 09/25/2012

CATx / Fiber Cross- Repeater

The Local Unit is connected via CATx (Fiber) connector A, The fiber connector B is
connected to the fiber connector A of the second Repeater. The Remote Unit is connected via
CATx (Fiber) connector B.

Reconfiguration of a Cross Repeater from „Local“ to „Remote“
or vice versa

The „Local“ device must carry the fiber GBIC in the connector B, the „Remote“ device in the
connector A. If the GBICs in your devices are plugged incorrect, you may alter the
configuration easily:

flap the shackle at the GBIC downwards

now pull the GBIC, using the shackle, out of the cage

plug the GBIC with soft force into the other cage until it snaps into place

flap the shackle at the GBIC upwards to lock the GBIC

Do not try to pull the GBIC out of the cage while the shackle
remains in the lock position (not flapped downwards). As long

as the shackle is flapped upwards, the GBIC is locked. Rough

pulling the GBIC out of the cage without flapping the shackle

downwards may result in damages at the GBIC and/or at the

device.

Local
Unit

Remote
Unit

Local

Remote