beautypg.com

Sw1 switch positions, Sw1 switch settings table – GAI-Tronics IDA1000A DC Remote Adapter Installation and Service Manual User Manual

Page 18

background image

Installation

Model IDA 1000A DC Remote Adapter

01/05

14

SW1 Switch Positions

There are eight section switches (SW1) on the front panel of the Model IDA1000A housing. See Figure 1
on page 4. A switch is closed when in the down position, and open in the up position. Refer to the tables
that follow for switch position and function information.

SW1 Switch Settings Table

SW1

Section Position

Function

1

Down

Up

Duplex hybrid enabled

Duplex hybrid disabled (default)

2

Up

Down

Transmit output range -15 dBm to 0 dBm

Transmit output range -25 dBm to -15 dBm (default)

3

Up with JU3 Out

Down with JU3 Out

Up with JU3 In

Down with JU3 In

Line input range: 32 mV ac to 150 mV ac

Line input range: 150 mV ac to 400 mV ac (default)

Line input range: 400 mV ac to 1.7 V ac

Line input range: 1.7 V ac to 4.5 V ac

4

Down

Up

Monitor function enabled only for duration of monitor command
(default).

Monitor function remains enabled after receiving a monitor command
and until a transmit command is received.

5 & 6

5 & 6 down

5 & 6 up

5 down

6 down

Special application: neither frequency is selected during receive
condition (default).

Radio remains on whatever frequency the last transmission occurred.

Radio reverts to frequency F1 after every transmission regardless of
frequency of previous broadcast (when SW1 section 6 is up).

Radio reverts to frequency F2 after every transmission regardless of
frequency of previous broadcast (when SW1 section 5 is up).

7

Down

Up

Provides line termination for incoming signals (default).

Does not terminate line.

8

Down

Up

Half-duplex operation (default).

Allows remote user to hear supervisory talk permit and button
acknowledge tone from the radio (requires SW1 section 1 to be down
and appropriate adjustment of Pot 3).