Conduit Installation Details (Surface-Mount Models)

GAI-Tronics recommends installing power lines in conduit to protect against accidental damage and
vandalism. To prevent moisture from entering the enclosure, we strongly recommend the following:
 Conduit should enter the enclosure from the bottom.
 Sealed fittings should be installed at all cable entry points.
 Silicone sealant or equivalent should be applied around and inside all conduit entries.
Please refer to the examples below for the recommended conduit installation details for surface-mount
telephones.

Figure 1. Bottom entry conduit recommended for

non-metallic enclosures

Figure 2. Top entry conduit installation for non-

metallic enclosures (NOT recommended)

Figure 3. Bottom entry conduit installation details

for metallic enclosures

Figure 4. Top entry conduit installation details for

metallic enclosures (NOT recommended)