Mounting – GAI-Tronics 10370-701 VoIP Interface/Amplifier Assemblies User Manual
Page 21
Pub. 42004-463A
Model 10370-70x and 10370-80x VoIP Interface/Amplifier Assemblies
Page 19 of 23
f:\standard ioms - current release\42004 instr. manuals\42004-463a.doc
09/13
Mounting
1. Loosen the four screws on the front cover. Open the front cover of the enclosure to the left.
2. Remove the cable connections between the front panel and rear enclosure.
3. Pull on the left side of the enclosure until the hinge pins pull loose to separate the front and rear
sections. Set the front half of the enclosure aside.
4. Determine the conduit or cable gland location on the rear enclosure. Drill spots have been provided
on top and bottom for use with either a chassis punch or hole saw. Cut or punch the appropriate size
hole(s) in the enclosure.
5. Use Myers ST-4 (1.25 inches) Scru-Tite hubs or equivalent. The hub(s) must be connected to the
conduit before being connected to the enclosure.
6. Each mounting hole in the enclosure is 0.280 inch in diameter. See Figure 5. Secure the rear
enclosure on the wall with screws or appropriate fasteners.
7. Route the ac power, speaker, input/output, and Ethernet cable through the conduit and into the
enclosure allowing adequate cable length to access terminal blocks. Secure any loose cabling making
sure loose wire does not contact the antenna.
8. Re-install the hinged front cover and re-connect the cables to the front cover.
Figure 5. Unit Component Identification