Voip pcba configuration, Voip pcba initial network configuration, Closing the voip interface/amplifier assembly – GAI-Tronics 10370-701 VoIP Interface/Amplifier Assemblies User Manual
Page 18

Pub. 42004-463A
Model 10370-70x and 10370-80x VoIP Interface/Amplifier Assemblies
Page 16 of 23
f:\standard ioms - current release\42004 instr. manuals\42004-463a.doc
09/13
VoIP PCBA Configuration
For the first time configuration of the VoIP PCBA, power the unit by connecting +24 V dc to TB101 and
connect Ethernet port of the VoIP PCBA to a 10/100 base-T Ethernet Network. Refer to Figure 6.
The easiest way to get started is to make a network connection to the unit and log on via a web browser.
The unit is initially set with a static IP address:
IP address
192.168.1.2
A user name and password will be requested. The initial factory settings are:
User Name
user
Password
password
Changing the user name and password is recommended. This security measure helps to prevent
unauthorized changes to the VoIP PCBA Interface’s configuration.
N
OTE
: The audio output level is set by configuring the Hands-free Output on the Audio Settings
webpage during the configuration of the speaker.
VoIP PCBA Initial Network Configuration
Each VoIP PCBA must be set up for the network prior to installation. Assign a local ID, domain, proxy,
and registrar.
Assign a host name
The host name provides identification of the different VoIP PCBAs on the
network.
Test
Verify that calls can be made successfully.
Maintain
Monitor alarms. Set up auto-updates.
Refer to Pub. 42004-482 for detailed programming instructions of this VoIP device.
Closing the VoIP Interface/Amplifier Assembly
Assemble the front and rear sections and tighten the front panel screws to 16 to 20 in-lbs. of torque.