Hardware installation – FSR HD-H70-SP User Manual
Page 11

11
ID
Name
Description
RS-232 pass through capability enabled
Firmware cannot be updated.
Update:
RS-232 pass through capability disabled
Firmware can be updated.
Hardware Installation
Warnings
Before the installation, disconnect the power supply from all the
devices.
Do not connect or disconnect cables from the Transmitter and
Receiver when they are powered on. To connect or disconnect
cables from the units, power them off first.
For best resolution and ESD performance Shielded CAT6A in a TIA
/ EIA 568B wiring configuration is recommended.Please use care
when installing, connecting and disconnecting cables.
1.
Connect the source to HDMI IN on the Transmitter via an HDMI cable.
2.
Connect an IR emitter cable to IR OUT and an IR receiver cable to IR IN on
transmitter.
3.
Connect a Display to HDMI OUT on Receiver.
4.
Connect an IR emitter cable to IR OUT and an IR receiver cable to IR IN on
the Receiver.
5.
Connect HDBT OUT on the Transmitter to HDBT IN on the Receiver via a
shielded CAT5e / CAT6 / CAT6A / CAT7 cable.
6.
Connect the power supply to either the transmitter or receiver.