FSR IT-SACWP User Manual
It-sacwp, Wallplate, Fsr inc

DESCRIPTION
The IT-SACWP Wallplate provides convenient, remote-
ly switched AC to power Projectors, displays and other
AC powered devices via a low voltage hard wired con-
trol input. Intended applications are for remote load
switching within one of our floor boxes or PWB wall
boxes. The unit is easily mounted in FSR’s CB-series,
PWB series, WB-X series, Floor Boxes, HuddleVU sta-
tions, flex control series, top shelf, etc. allowing remote
AC power control of amplifiers, switchers and more.
The single gang, Decora style, 15 amp rated, switched
AC outlet wires directly to a 15 amp branch circuit via
the input harness at the back of the unit. Connections
to the branch circuit are made using the included wire
nuts.
The switching technology is relay based for reliable
operation and minimal heat dissipation. Control is
accomplished via the fixed 2 position screw terminal
connector. A green LED is provided for visual indication
of the relay state. Two standard models are available to
allow control from either 12 or 24VDC systems. See
ordering information.
Applications include: Remote power switching for
self-powered stage monitors as well as vocalist,
musician headphone mixing systems. This allows a
power sequencer to turn on AC power to stage
speakers. Useful for any type of stage, auditorium,
or house of worship scenario.
IT-SACWP
Wallplate
• 14 AWG solid wire 6” free length,
(L, N, G) for AC input
• Wire nuts included
• White wall plate with black AC outlet
• LED relay state indicator
• Screw terminals for quick and easy control
input wiring
• Compact 1-gang form factor
DESCRIPTION
FEATURES
FEATURES
SPECIFICATIONS
SPECIFICATIONS
ORDERING INFORMATION
ORDERING INFORMATION
FSR Inc.
244 Bergen Boulevard, Woodland Park, NJ 07424
Phone: 973.785.4347 · Fax: 973.785.4207
Web: www.fsrinc.com · E-mail: [email protected]
LIT1478A
AV Products Group
IT
-SACWP
Device rated current
12 A (switches standard 15 amp circuit
subject to a 20% UL derating)
Operate time
15 ms max
IT-SACWP operates from a
12VDC@ 90mA drive signal.
(The HuddleVU system uses the 12VDC version.)
IT-SACWP-24 operates from a
24VDC@ 50mA drive signal
43050