CB-224P/SP INSTALLATION INSTRUCTIONS

1.

10. INSTALL 14-3/8" x 22-3/4" DROP CEILING MATERIAL (SUPPLIED

BY CUSTOMER) INTO DOOR. BEND CAPTURE TABS OVER
CEILING PANEL TO HOLD IN PLACE.

14-3/8" x 22-3/4"

DROP CEILING

PANEL MATERIAL

(SUPPLIED BY

CUSTOMER)

LOOSEN SCREWS
TO OPEN DOOR

11. REMOVE CEILING BOX DOOR (SEE STEP 9), REMOVE

(2) #8-32 SCREWS AND ADJUSTMENT BAR COVER. SUPPORT
ADJUSTMENT BAR COVER WHILE REMOVING SCREWS.
POLE MOUNT FLANGE COVER IS NOT FASTENED AND JUST
SLIPS OUT. INSTALL (2) 4" WIDE (SEE NOTE) DROP CEILING
PANELS MATERIAL (SUPPLIED BY CUSTOMER) INTO POLE
ADJUSTMENT BAR. CUT LENGTH AS NEEDED BASED ON
POLE MOUNT POSITION.

NOTE: 4" x 9" PANEL SIZE IS ONLY VALID WHEN POLE MOUNT
FLANGE IS CENTERED ON THE POLE ADJUSTMENT
BAR (DEFAULT FACTORY INSTALLED LOCATION). IF
POLE
MOUNT IS RELOCATED PANELS WILL NEED TO
BE CUT-TO-FIT.

(4) CAPTURE

TAB

POLE MOUNT FLANGE
(SHOWN CENTERED)

POLE ADJUSTMENT BAR

TO INSTALL AC MAIN POWER INTO THE UNIT, REMOVE
THE AC ACCESS PLATE BY REMOVING (4) #8-32
SCREWS, AS SHOWN. WIRING MUST BE PERFORMED
BY A QUALIFIED ELECTRICIAN ONLY. WIRING MUST BE
DONE IN ACCORDANCE WITH ALL NEC AND OTHER
APPLICABLE CODES. RE-INSTALL AC ACCESS PLATE
AFTER AC WIRING IS COMPLETE.

2.

DROP-DOWN
RACK-MOUNT
CARRIAGE

a

b

IF POLE MOUNT FLANGE IS TO BE LEFT AT FACTORY
POSITION, PROCEED TO STEP 7. IF FLANGE IS TO BE
RE-POSITIONED, OR IF INSTALLING FAN KIT, REMOVE
CEILING BOX DOOR. LOOSEN SCREWS TO OPEN DOOR.
(a) PUSH DOOR UP TOWARDS CEILING AND (b) PUSH
TOWARDS DROP-DOWN RACK-MOUNT CARRIAGE -
REVERSE PROCEDURE TO INSTALL. DISCONNECT
SAFETY CABLE TO COMPLETELY REMOVE DOOR.

3.

LOOSEN SCREWS
TO OPEN DOOR

FSR Inc.

244 Bergen Boulevard, Woodland Park, NJ 07424

Phone: 973.785.4347 - Fax: 973.785.4207
Web: www.fsrinc.com - E-mail: [email protected]

CEILING TILE INSTRUCTIONS

DOOR IS REMOVABLE.

(a) PUSH DOOR UP

TOWARDS CEILING AND

(b) PUSH TOWARDS

DROP-DOWN

RACK-MOUNT CARRIAGE

- REVERSE PROCEDURE

TO INSTALL.

a

b

4" WIDE DROP CEILING PANEL

MATERIAL - SEE STEP 10 NOTE

(SUPPLIED BY CUSTOMER)

(2) #8-32 x 1/4"-LONG

PAN HEAD SCREW

POLE MOUNT FLANGE COVER

ADJUSTMENT
BAR COVER

DISCONNECT SAFETY

CABLE TO COMPLETELY

REMOVE DOOR.

DROP-DOWN
RACK-MOUNT
CARRIAGE

(4) #8-32 x 1/4"- LONG
PAN HEAD SCREW

AC POWER INPUT

WIRING MUST BE

PERFORMED BY

A QUALIFIED

ELECTRICIAN ONLY

AC ACCESS
PLATE

INSTALL CB-224P/SP TO A STRUCTURAL CEILING ABLE TO
SUPPORT FIVE TIMES THE NOTED GROSS WEIGHT. USE
APPROPRIATE MOUNTING METHODS BASED ON LOCAL
BUILDING CODES. INSTALL SAFETY CABLE AS REQUIRED BY
LOCAL BUILDING CODES. ROUTE CONDUITS TO BOX AS
REQUIRED.

NOTE: MAXIMUM GROSS WEIGHT - 125 LBS

NOTE: THREADED ROD IS THE
RECOMMENDED CEILING BOX
MOUNTING SUSPENSION
(SHOWN), TO MINIMIZE
FIXTURE TILTING DUE
TO THE WEIGHT OF ANY
SUSPENDED EQUIPMENT.

AVAILABLE KITS (SOLD SEPARATELY):
CB-MNT1 - CABLE INSTALLATION KIT
CB-THRD - THREADED ROD INSTALLATION KIT

STRUCTURAL
MEMBER

ALL MOUNTING HARDWARE
SUPPLIED BY CUSTOMER

STRUCTURAL
CHANNEL

THREADED ROD OR CABLE TO

BE PLUMB WITH CEILING AND FLOOR

14 GA. STEEL TIE WIRE MAY BE USED

(SUPPLIED BY CUSTOMER OR USE FSR KIT)

AT 70,000 PSI TENSILE STRENGTH OR

BETTER AS REQUIRED BY BUILDING CODES.

NOTE: WIRES SUPPORT CEILING

BOX, AND ARE NOT SAFETY CABLES

ROUTE CONDUIT
(SUPPLIED BY
CUSTOMER) TO
KNOCKOUTS
AS REQUIRED

BRACKET - FSR'S
THREADED ROD
INSTALLATION KIT
(HARDWARE SUPPLIED
BY CUSTOMER)