FSR FL-FRK-605P User Manual
FSR Equipment
![background image](https://www.manualsdir.com/files/786348/content/doc001.png)
FSR
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
43024
LIT1429B
1. PRIOR TO CUTTING THE 17-1/4" x 20" OPENING IN THE DECK SURFACE,
REFER TO CUSTOMER SPECIFICATIONS FOR ORIENTATION OF FLOOR
BOX. ORIENTATION OF OPENING WILL BE BASED ON ORIENTATION OF
PAN (SEE LABEL IN PAN BOTTOM).
NOTE: CONSULT STRUCTURAL ENGINEER BEFORE CUTTING
DECKING. ADD ADDITIONAL SUPPORTS AS REQUIRED PER
ENGINEERING INSTRUCTIONS.
17-1/4" x 20"
OPENING
17-1/4" x 20"
OPENING
FORMED DECK
STEEL CORRUGATED DECK
2. INSTALL PAN IN CUT-OUT AND SECURE TO DECKING WITH
HARDWARE (BY OTHERS) OR WELDING.
STEEL CORRUGATED DECK
FORMED DECK
DO NOT SECURE
FLANGES TO FORM
FROM TOP OF FORM
8.
9. PULL WIRES AND CABLES TO BOX AS NECESSARY (CONFIGURING OF GANG MOUNTING
BRACKETS MAY BE REQUIRED - REFER TO FLOOR BOX INSTALLATION INSTRUCTIONS).
TERMINATE WIRES AND CABLES TO ELECTRONIC COMPONENTS, AND INSTALL
ELECTRONIC COMPONENTS ONTO GANG MOUNTING BRACKETS. REINSTALL
TEMPORARY COVER IF FINISHED COVER IS TO BE INSTALLED AT A LATER DATE.
NOTE: READ FLOOR BOX INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION.
FL-FRK-605P INSTALLATION INSTRUCTIONS FOR CORRUGATED OR FORMED DECK
GANG
MOUNTING
BRACKET
INSTALLED
ELECTRONIC
COMPONENT
NOTE: FOR CORRUGATED DECK PAN MUST BE CENTERED ON
PEAK OR VALLEY.
PAN CENTER LINE
PAN CENTER LINE
PAN CENTER LINE
20"
20"
17-1/4"
17-1/4"
BEND DOWN
TABS AS
NEEDED TO
SECURE PAN
TO DECK
ROUTE CONDUITS AS REQUIRED TO FLOOR BOX.
TWIST WIRE
AROUND
NAIL/SCREW.
CUT WIRE
FOR EASY
REMOVAL
OF FORM
NAIL/SCREW
INTO FORM
FROM BELOW,
IN LINE WITH
EMBOSS
UNDERSIDE VIEW
CUT-OUT
HOLE
WIRE - 13"-14" LONG,
BEND IN MIDDLE, WIRE
DOWN THRU CUT-OUT
HOLE IN FORM