The instruction plate is firmly attached to the purifier

for quick reference to important instructions. The plate

does not replace the complete manuals supplied with

the purifer. Do not remove or deface the plate.

SAFETY

8DM Series purifiers are designed and constructed

with safety as a prime consideration. Each purifier is

pressure tested to 1½ times its maximum operating

pressure.

DANGER

The following safety rules are crucial to en-

sure safe purifier operation. Failure to follow

these 9 important rules may result in purifier

damage, inadequate purification, severe ill-

ness, injury or death.

1. Do not allow grossly contaminated air into the pu-

rifier inlet. See Table I for maximum allowable in-

let carbon monoxide concentration.

2. Do not allow oxygen-deficient air into the purifier

inlet. The purifier will not increase the oxygen

content of air.

3. Contact Deltech if any unusual contaminants may

be in the compressed air. The purifier removes

only oil, moisture, particulates and carbon monox-

ide.

4. Do not operate the purifier at pressures, tempera-

tures or flows above the maximum conditions

stamped on the data plate attached to the side

panel.

5. Do not use the purifier for any gases other than

compressed air.

6. Vent purifier internal pressure to the atmosphere

before disassembling any purifier parts.

7. Do not readjust the purifier without factory

authorization. The purifier is fully adjusted at the

factory.

8. Use only genuine Deltech replacement parts, ele-

ments and cartridges. Deltech bears no responsi-

bility for hazards that result if Deltech equipment

is used with non-approved parts.

9. Replace all cartridges according to the preventive

maintenance schedule starting on page 13 in this

manual.

INSTALLATION

Receiving and Inspection

Immediately on receipt of the purifier, check for dam-

age that may have occurred during shipping. If there is

any damage, do not install or attempt to repair the pu-

rifier. Installation and use of damaged equipment may

void the warranty or cause serious injury.

If the purifier is damaged, contact your local distribu-

tor. Since the purifier is shipped F.O.B. New Castle,

Delaware, the carrier is legally responsible for any

damage incurred during shipping. Shipping damage is

not covered by the purifier warranty.

2

Pyramid 8000

®

Series Purifiers (Bulletin 289)

Danger Label: Grossly Contaminated Air

Part No. 56DE152A

Purifier Data Plate

Part No. 44DE23A