beautypg.com

Shut down 10, Shutdown, Warning label: switch must be on – Deltech Fitness PYRAMID 8000 User Manual

Page 16: Part no. 58de27a, Maintenance procedures

background image

manual) for drain valve maintenance instruc-

tions.

Before restarting the purifier, open the manual drain

on the particulate filter. If no liquid discharges, close

drain.

WARNING

If any liquid discharges from the particulate

filter, immediately stop using the purifier out-

let air for breathing. Replace all elements and

the catalyst vessel. Contact Deltech before

restarting the purifier.

Weekly

Open the manual drain on the particulate filter.

If any liquid discharges, immediately stop using

the purifier outlet air for breathing. Check the

coalescing filter drain valve as described under

“Daily” maintenance, above. Replace all filter

elements and the catalyst vessel.

Monthly

Remove screen from front of condenser and

clean condenser coils of accumulated dust and

dirt with a soft brush.

Every four months

Replace activated carbon filter. See Mainte-

nance Procedures for instructions.

Yearly

Replace catalyst vessel.

To replace the catalyst vessel, follow the procedure for

replacing the activated carbon filter (above). The con-

nection sizes on the catalyst vessel are different from

those on the activated carbon filter to prevent inter-

changing these components.

MAINTENANCE PROCEDURES

Carbon or Catalyst Vessel Replacement

Follow this procedure to replace the activated carbon

filter or the catalyst vessel (the word “vessel”will be

used to indicate both):

1. Shut down the purifier according to the Shutdown

procedure.

2. Remove the top cabinet panel to expose the vessel,

and remove side panels as necessary to reach the

securing clamp and pipe connections.

3. Models 8DM100 and 8DM150—set up the boom

assembly (see “Boom Assembly” section) and at-

tach the hoist to the top of the vessel.

4. Disconnect the unions on the top and bottom of

the vessel.

5. Open the hinged clamps securing the vessel to its

support bracket.

12

Pyramid 8000

®

Series Purifiers (Bulletin 289)

Caution Label: Use of Charcoal Element

Part No. 56DE197A

Danger Label: Use of Catalyst Vessel

Part No. 56DE196A