16

Pyramid 8000

®

Series Purifiers (Bulletin 289)

SYMPTOM

POSSIBLE CAUSE

REMEDY

Refrigerant compressor running.

(REFRIG DISCHARGE tempera-

ture light flashes, temperature is

outside normal range or alarm

set point is reached.)

1. Purifier turned on less than

one hour.

1. If light is still on after one hour, do not use puri-

fier. Contact Deltech.

2. Loss of refrigerant charge.

2. Have refrigeration mechanic locate and repair

leak. Recharge.

3. Ambient temperature below

50°F.

3. Relocate purifier, or heat area.

Refrigerant compressor cut out

by high refrigerant head pressure

control.

1. Condenser fouled or clogged.

1. Clean condenser coils (see Maintenance,

Monthly).

2. Fan motor stopped.

2. Repair or replace fan motor.

3. Inlet air temperature too high.

3. Check aftercooler discharge temperature. Re-

duce temperature to 120°F max.; reduce airflow if

temperature is higher than 100°F (see Airflow sec-

tion).

4. Air in refrigeration system.

4. Have refrigeration mechanic locate and repair

leak. Recharge.

Liquid in particulate filter.

1. Failure of purifier drains or

automatic drain valves on after-

cooler/separator.

1. Shut down purifier. Check drain valves, clean,

repair or replace as necessary. Replace activated

carbon filter and catalyst vessel before restarting.

2. Failure of refrigeration system.

2. Check above symptoms.