Page 18: Carbon or catalyst vessel replacement, Caution label: use of charcoal element, Part no. 56de196a

background image

WARNING

To restart the purifier, follow the procedure

described in the Start-Up section of this man-

ual.

Afterfilter Element Replacement

To replace the element:

1. Shut down the purifier according to the Shutdown

procedure.

2. Open the manual drain valve at the bottom of the

filter.

3. Remove the threaded bowl from the top casting.

4. Remove the wing nut and element support plate

from the tie rod; the element with support core

will drop.

5. Slide the used element off the support core.

6. Clean the bowl with soap and water. Do not use

solvents. Dry the bowl thoroughly.

7. Insert a new element on the support core.

8. Slide the element with support core onto the tie

rod.

9. Replace the element support plate and wing nut.

10. Reattach the bowl to the top casting.

11. Close the manual drain.

WARNING

To restart the purifier, follow the procedure

described in the Start-Up section of this man-

ual.

System Operation Monitor Programming

In some cases, such as a strong power surge from

lighting, the System Operation Monitor may lose its

programming. Perform the following steps to repro-

gram the system operation monitor.

1. Turn the power switch to the OFF position.

2. Jumper across terminal E1 (see Figure 3) on the

back of the display.

3. Starting with the top button (SCAN/SEEK), press

each of the four buttons on the monitor.

4. Press the PUSH TO TEST button again.

5. Press the TIME ADJUST button until the correct

program is selected.

Version

Program

8S

All Models

6. Press the PUSH TO TEST button. The System

Operation Monitor is now reprogrammed.

14

Pyramid 8000

®

Series Purifiers (Bulletin 289)

E1

Figure 3. System Operation Monitor Board Layout