To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the ambient conditions. Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)

1.7 Nameplate and safety labels


1.7.1 Nameplate
For details of nameplate, see the Declaration of
Conformity.
Where a unit is ATEX Group II Category
1 below the soleplate there is an additional ATEX
marking plate (see section 1.6.4.2 Marking).

1.7.2 Safety labels


Oil lubricated units only:

1.8 Specific machine performance

For performance parameters see section 1.5, Duty
conditions
. Where performance data has been
supplied separately to the purchaser these should be
obtained and retained with these User Instructions if
required.

1.9 Noise level

Attention must be given to the exposure of personnel
to the noise, and local legislation will define when
guidance to personnel on noise limitation is required,
and when noise exposure reduction is mandatory.
This is typically 80 to 85 dBA.

The usual approach is to control the exposure time to
the noise or to enclose the machine to reduce emitted
sound. You may have already specified a limiting
noise level when the equipment was ordered,
however if no noise requirements were defined, then
attention is drawn to the following table to give an
indication of equipment noise level so that you can
take the appropriate action in your plant.

Pump noise level is dependent on a number of
operational factors, flow rate, pipework design and
acoustic characteristics of the building, and so the
values given are subject to a 3 dBA tolerance and
cannot be guaranteed.

Similarly the motor noise assumed in the “pump and
motor” noise is that typically expected from standard
and high efficiency motors when on load directly driving
the pump. Note that a motor driven by an inverter may
show an increased noise at some speeds.

If a pump unit only has been purchased for fitting with
your own driver then the “pump only” noise levels in the
table should be combined with the level for the driver
obtained from the supplier. Consult Flowserve or a
noise specialist if assistance is required in combining
the values.

It is recommended that where exposure approaches
the prescribed limit, then site noise measurements
should be made.

The values are in sound pressure level L

pA

at 1 m

(3.3 ft) from the machine, for “free field conditions
over a reflecting plane”.

For estimating sound power level L

WA

(re 1 pW) then

add 14 dBA to the sound pressure value.

2 TRANSPORT AND STORAGE

2.1 Consignment receipt and unpacking

Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for its
completeness and that there has been no damage in
transportation. Any shortage and/or damage must be
reported immediately to Flowserve Pump Division and
must be received in writing within one month of receipt
of the equipment. Later claims cannot be accepted.

Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to side
walls of the box or equipment.