Typical sound pressure level L
pA
at 1 m reference 20
µ
Pa, dBA
3 550 r/min
2 900 r/min
1 750 r/min
1 450 r/min
Motor size 
and speed 
kW (hp)
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
<0.55(<0.75)
72
72
64
65
62
64
62
64
0.75 (1)
72
72
64
66
62
64
62
64
1.1 (1.5)
74
74
66
67
64
64
62
63
1.5 (2)
74
74
66
71
64
64
62
63
2.2 (3)
75
76
68
72
65
66
63
64
3 (4)
75
76
70
73
65
66
63
64
4 (5)
75
76
71
73
65
66
63
64
5.5 (7.5)
76
77
72
75
66
67
64
65
7.5 (10)
76
77
72
75
66
67
64
65
11(15)
80
81
76
78
70
71
68
69
15 (20)
80
81
76
78
70
71
68
69
18.5 (25)
81
81
77
78
71
71
69
71
22 (30)
81
81
77
79
71
71
69
71
30 (40)
83
83
79
81
73
73
71
73
37 (50)
83
83
79
81
73
73
71
73
45 (60)
86
86
82
84
76
76
74
76
55 (75)
86
86
82
84
76
76
74
76
75 (100)
87
87
83
85
77
77
75
77
90 (120)
87
88
83
85
77
78
75
78
110 (150)
89
90
85
87
79
80
77
80
150 (200)
89
90
85
87
79
80
77
80
200 (270)
1
1
1
1
85
87
83
85
300 (400)
–
87
90
85
86
1
The noise level of machines in this range will most likely be of values which require noise exposure control, but typical values are inappropriate.
Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA.
 
Each product has a unique serial number. Check 
that this number corresponds with that advised and 
always quote this number in correspondence as well 
as when ordering spare parts or further accessories. 
 
2.2 Handling
Boxes, crates, pallets or cartons may be unloaded 
using fork lift vehicles or slings dependent on their size 
and construction. 
 
2.3 Lifting
To avoid distortion, the pump unit
should be lifted as shown. 
 
Pumps with drivers over approximately 7.5 kW, are 
supplied with the pump packed as a separate item 
from the driver. These and should be lifted 
separately into their installed position, using lifting 
points on the pump soleplate, and on the motor. 
When lifting pumps with drivers fitted,
the resulting center of gravity may be above the lifting 
points, and the method of slinging must prevent the 
machine tipping during the lift. 
Slings, ropes and other lifting gear must be positioned 
where they cannot slip and where a balanced lift is 
obtained. 
 
For improved stability unbolt the driver and lift the 
driver and pump separately. 
For lifting the driver refer to the 
dimension drawing of the driver. 
 
 
 
Lift points for the pump or the pump 
and the driver. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 