2 pump lubricants – Flowserve CPXV fitted with WW User Manual
Page 16

CPXV - WW/CW USER INSTRUCTIONS ENGLISH 85392698 10-09
Page 16 of 36
flowserve.com
5.2 Pump lubricants
5.2.1 Recommended oil lubricants
* Note that it normally takes 2 hours for bearing temperature to stabilize and the final temperature will depend on the ambient, r/min, pumpage
temperature and pump size. Also some oils have a greater viscosity index than the minimum acceptable of 95 (eg Mobil DTE13M) which may
extend the minimum temperature capability of the oil. Always check the grade capability where the ambient is less than -5 ºC (-23 ºF).
†
Use LSC for oil mist. Oil parameters provide flash point >166 ºC (331 ºF), density >0.87 @ 15 ºC (59 ºF), pour point of -10 ºC (14 ºF) or lower.
5.2.2 Bearing sizes and grease/oil capacities
Shaft size
1
2
3
4
Medium duty thrust bearing duplex back-to-back AC
3306C3
3309C3
3311C3
3313C3
Heavy duty thrust bearing duplex back-to-back AC
7306 pair
7309 pair
7311 pair
7313 pair
Approximate oil fill quantities - litre (fl.oz)
0.6 (20)
0.95 (32)
1.0 (34)
0.9 (31)
Grease quantities – g (oz)
14 (0.5)
25 (0.9)
35 (1.2)
46 (1.6)
Note: The bearing sizes do not constitute a purchasing specification.
5.2.3 Recommended grease lubricants
Grease
NLGI 2 *
NLGI 3
Temperature
range
-20 to +100 ºC
(-4 to +212 ºF)
-20 to +100 ºC
(-4 to +212 ºF)
Designation
according to DIN
KP2K-25
KP3K-20
BP
Energrease LS-EP2
Energrease LS-EP3
Elf
Multis EP2
Multis EP3
Fuchs
RENOLIT EP2
RENOLIT EP3
Esso
Beacon EP2
Beacon EP3
Mobil
Mobilux EP2
Mobilux EP3 **
Q8
Rembrandt EP2
Rembrandt EP3
Shell
Alvania EP2
Alvania EP2
Texaco
Multifak EP2
Multifak EP3
SKF
LGEP 2
* NLGI 2 is an alternative grease and is not to be mixed with other
grades.
** Standard pre-packed grease for fitted antifriction bearings.
5.2.4 Recommended fill quantities
Refer to section 5.2.2, Bearing sizes and grease/oil
capacities.
5.2.5
Lubrication schedule
5.2.5.1 Oil lubricated bearings
Normal oil change intervals are 2 000 operating hours.
For pumps on hot service or in severely damp or
corrosive atmosphere, the oil will require changing more
frequently. Lubricant and bearing temperature analysis
can be useful in optimizing lubricant change intervals.
The lubricating oil should be a high quality mineral oil
having foam inhibitors. Synthetic oils may also be
used if checks show that the rubber oil seals will not be
adversely affected.
The bearing temperature may be allowed to rise to
50 ºC (90 ºF) above ambient, but should not exceed
82 ºC (180 ºF) (API 610 limit). A continuously rising
temperature, or an abrupt rise, indicates a fault.
Pumps that handle high temperature liquids may
require their bearings to be cooled to prevent bearing
temperatures exceeding their limits.
Oil
Splash / force feed / purge oil mist lubrication
Viscosity cSt
@ 40 ºC
32
46
68
Oil temperature range *
-5 to 65 ºC
(23 to 149 ºF)
-5 to 78 ºC
(23 to 172 ºF)
-5 to 80 ºC
(23 to 176 ºF)
C
e
n
tr
if
u
g
a
l
p
u
m
p
lu
b
ri
c
a
ti
o
n
Designation to ISO 3448
and DIN51524 part 2
ISO VG 32
32 HLP
ISO VG 46
46 HLP
ISO VG 68
68 HLP
BP Castrol
†
Energol HLP-HM 32
Energol HLP-HM 46
Energol HLP-HM 68
ESSO
†
NUTO HP 32
NUTO HP 46
NUTO HP 68
ELF/Total
†
ELFOLNA DS 32
Azolla ZS 32
ELFOLNA DS 46
Azolla ZS 46
ELFOLNA DS 68
Azolla ZS 68
LSC (for oil mist)
LSO 32 (Synthetic oil)
LSO 46 (Synthetic oil)
LSO 68 (Synthetic oil)
ExxonMobil
†
Mobil DTE 24
Mobil DTE 25
Mobil DTE 26
Q8
†
Q8 Haydn 32
Q8 Haydn 46
Q8 Haydn 68
Shell
†
Shell Tellus 32
Shell Tellus 46
Shell Tellus 68
Chevron Texaco
†
Rando HD 32
Rando HD 46
Rando HD 68
Wintershall (BASF Group)
†
Wiolan HS32
Wiolan HS46
Wiolan HS68
O
il
c
o
m
p
a
n
ie
s
a
n
d
lu
b
ri
c
a
n
ts
Fuchs
†
Renolin CL 32
Renolin CL 46
Renolin CL 68