Flowserve S-series PolyChem User Manual
Page 27

USER INSTRUCTIONS POLYCHEM S-SERIES ENGLISH 71569207 11-08
Page 27 of 52
flowserve.com
If maintenance work has been carried
out to the sites electrical supply, the direction of 
rotation should be re-checked as above in case the 
supply phasing has been altered. 
Figure 5-11
 
5.4.2 Coupling installation 
The coupling should be installed as
advised by the coupling manufacturer. Pumps are 
shipped without the spacer installed. If the spacer 
has been installed to facilitate alignment, then it must 
be removed prior to checking rotation. Remove all 
protective material from the coupling and shaft before 
installing the coupling. 
 
5.5 Guarding
Power must never be applied to the
driver when the coupling guard is not installed. 
 
Flowserve coupling guards are safety devices intended 
to protect workers from inherent dangers of the rotating 
pump shaft, motor shaft and coupling. It is intended to 
prevent entry of hands, fingers or other body parts into a 
point of hazard by reaching through, over, under or 
around the guard. No standard coupling guard provides 
complete protection from a disintegrating coupling. 
Flowserve cannot guarantee their guards will 
completely contain an exploding coupling. 
 
5.5.1 Clam shell guard - standard 
The standard coupling guard for all PolyChem S-series 
pumps is the “clam shell” design and is shown in Figure 
5-12. It is hinged at the top and it can be removed by 
loosening one of the foot bolts and sliding the support 
leg out from under the cap screw (note that the foot is 
slotted). The leg can then be rotated upward and half of 
the guard can be disengaged (unhinged) from the other. 
Only one side of the guard needs to be removed. To 
reassemble simply reverse the above procedure. 
Figure 5-12
The coupling guard shown in Figure 5-12 conforms to 
the USA standard ASME B15.1, “Safety standard for 
mechanical power transmission apparatus.” 
Flowserve manufacturing facilities worldwide conform 
to local coupling guard regulations. 
 
5.5.2 ClearGuard™ - optional 
Flowserve offers as an option a ClearGuard™, which 
allows you to see the condition of the coupling. (See 
Figure 5-13.) This guard can be used in place of the 
existing clamshell guard described above. 
Disassembly of the ClearGuard™ is accomplished by 
removing the fasteners that hold the two guard halves 
together followed by removing the foot bolts and 
rotating the support leg out of the slot on the guard. 
Figure 5-13
5.5.3 Trimming instructions 
In order to correctly fit the pump/motor configuration, 
each guard must be trimmed to a specific length. 
This trimming is done on the motor end of the guard. 
a) Measure minimum distance from the center of 
mounting hole in the baseplate to the motor. 
(If clam shell guard proceed to step c.) 
b) Locate a reference center in the slot of the
ClearGuard™ coupling guard flange, see figure 
5-14. Transfer the length measurement to the 
guard using this reference center. 
c) Trim the motor end of the guard according to the
above measurement. Trimming is best done with 
a band saw, but most other types of manual or 
power saws give acceptable results. Care must 
be taken to ensure that there is no gap larger 
than 6 mm (0.24 in.) between the motor and the 
coupling guard. 