Installation Do’s & Don’ts

Do Don’t

Always use a Fuel Proof Pipe Thread Sealant

when assembling fittings into fuel system

components, (Locktite PST, Rector Seal, or

equivalent).

Never use Teflon Tape!

Use thin wall, low pressure, full flow type

NPT or NPTF hose barb fittings.

If possible avoid using Push-Lok, Barb-Tite,

JIC or SAE swivel fittings. If used, always

install

Copper AP-50 sealing washers or Flaretite

fitting seals onto JIC and SAE swivel fittings.

Double clamp all hose barb fittings.

Minimize the use of 90º elbow fittings.

Install Sensors as far from the engine as practical.

Fuel must travel, “Up-hill” at least 1 or 2 inches

after leaving the Diesel Return Sensor, and all

Gasoline Sensors. Verify correct orientation and

fuel flow direction.


Avoid bolting or mounting

sensor(s) directly onto the engine.

Always install Diesel Forward Sensor/Pulsation

Damper assemblies and Gasoline Sensors in the

Fuel Pump’s Inlet or Vacuum line.

Limit Sensor/Pulsation Damper assembly

Operating Pressure to 20 PSI or Less.

Try to use A-1 Fabric Braid Fuel Hose.

If possible avoid using steel braid,

“Aeroquip” type hose, hard pipe or metal tube.

Always use 30-micron primary filters on Diesel

systems. 20 and 10-micron filters are also

acceptable if required by the engine manufacturer.

Avoid 2 or 5-micron primary filters.

Wire with Shielded Cable on Diesel installations.

If possible use a dedicated shielded wire pair for

Magnetic Pickup Tachometer Senders.

Never use unshielded wires on

Magnetic Pickup Tachometer Senders.

Connect all Negative wires to a Battery Minus

Buss or directly to the Battery’s Negative

Terminal.

Connect or, “Ground” wire shields / shield drains

to the engine block or vessel bonding system.



Never connect Negative, (Battery Minus) wires

to the Vessels Hull, Engine Block,

or other machinery.

On Instruments with a GPS interface, connect

FloScan’s Data (+) to the GPS signal output.

Connect Data (–) to a Battery Minus buss.

Do not connect FloScan’s Data (–)

to the GPS Data (–).

Always use non-illuminated switches for Totalizer

Reset, Port/Starboard Select, Hours/Synch, and

GPH/MPG

.


Never use illuminated, or back-lit switches.