2. Slide a lock washer onto two, 1¼” bolts.

3. Chose your 90° mounting bracket option. Assemble the

1¼” bolts through the angle and flat brackets into the
Pulsation Damper base.

4. Tighten the bolts a little past hand tight, compressing the

lock washers slightly.

5. Install the two long spacers between the Sensor body and

flat bracket.

6. Slide the two, 2¼” bolts through the Sensor body, spacers

and flat bracket.

7. Grasp the Pulsation Damper and hold the flat bracket

against the Pulsation Damper’s base. Verify that the
Sensor’s base is perpendicular to the flat bracket.

8. If the Sensor and spacers are flush with the flat bracket,

install flat washers and ESNA nuts onto the 2¼” bolt ends
and tighten until snug. The Pulsation Damper and Sensor
bolts should be tightened evenly.

9. If a small air gap is present between Sensor and spacers,

place one flat washer between each spacer and the flat
bracket.

10. Install flat washers and ESNA nuts onto the bolt ends and

tighten until snug. The Pulsation Damper and Sensor bolts
should be tightened evenly.














(Continued on next page)