10. Connect the orange wire, terminal #4 to the instrument light power (+12 VDC) and the black/orange wire, terminal #12 to the

instrument light ground.


Installing the PULSE instrument (85, 86 Series)

1.

If you have an existing tachometer on this side, label the signal lead(s) and remove the power and ground leads and the
tachometer. Install the meter labeled on the back “Pulse”. Plug in the white connector labeled “Pulse” to the meter labeled
“Pulse” and separate out the wires coming from this connector.


2.

See the tachometer section of the “Mechanical & Wiring Overview Installation” sheet (4001-325-00) for connection of the
yellow wire, terminal #8 and the violet wire, terminal #16.


3.

The black wire, terminal #5 (system ground) connects to the junction of the black wires from the feed and return flow sensors
and goes to battery ground. This instrument uses a single point ground system to reduce noise interference and must have only
one connection to battery ground.


4.

The white wire, terminal #6 (signal) connects to the white wire of the feed flow sensor.


5.

The brown wire, terminal #14 (signal) connects to the white wire of the return flow sensor.


6.

The PULSE meter requires one switch for the Gallons reset. Connect the black wire, terminal #15 to one of the terminals of the
Gallons reset switch. Connect the green wire, terminal #10 to the other side of the Gallons reset switch. This switch can be
either a normally open momentary push button or a spring-loaded toggle switch. Mount the switch with ON in the UP position.
This puts the meter in the reset mode when the switch is up.


7.

Connect the red wire, terminal #9 to the engine ON side of the engine key switch.

This completes the wiring section of your installation. Read the “Checking the Installation” and “Checking the Calibration”