TROUBLESHOOTING

Series 7500/7600 8500/8600 9500/9600 Multifunction Instrument

BEFORE CALLING FOR ASSISTANCE, COMPLETE THESE TROUBLESHOOTING CHECKS AND RECORD YOUR
FINDINGS. TECHNICAL SUPPORT REQUIRES THIS INFORMATION BEFORE A RETURN AUTHORIZATION WILL BE
ISSUED. IT TAKES ABOUT 20 MINUTES AND IS VERY IMPORTANT IN ANALYZING SYSTEM PROBLEMS.


Before starting, record Instrument

model number and switch settings.

MODEL # ________________________

SERIAL # ________________________

UPPER BLACK________ RED________ GREEN________

LOWER BLACK or RECESSED ARROW________


FAULT

PROBABLE CAUSE

SEE SECTION:

Blank LCD Display

Wiring

Sections II, III

No Back-Lighting

Wiring

Sections III

High or Low Totalizer reading. Over 10%.

Calibration

Calibration sheet

Incorrect flow sensor

Operations sheet

Incorrect switch settings

Calibration sheet

Vacuum leak

Section IX

Fluctuating GPH Readings

Vacuum leak / Pulsations

Sections VIII, IX, X

No GPH or Totalizer Readings

Wiring

Sections II, V, VI

Sensor orientation

Installation sheet, Section IV

High, Low or No Tachometer Reading

Wiring

Installation sheet, Section II

Calibration

Calibration

sheet

Continuity

Section

VI

In-synch with engine or

Glen Denning cable whip

Section VII

No Forward or Return Sensor Readings

Wiring /Instrument failure Sections I, II, IV, V, VI

Sensor Failure

Section I, IV

High Forward or Return Sensor Readings

Vacuum Leak

Section IX

Incorrect switch settings

Calibration sheet

Sensor

orientation

Section

XI

I. DIAGNOSTIC TEST:

1.

Start engine(s). For 2 seconds after powering up, the Instrument will show all 8s. During this time, quickly cycle the Totalizer-
Reset Switch from its’ run position to reset and back at least twice. This puts the Instrument into Show Switches Mode for 20
seconds. Record these readings below.

HOURS: ____________:_____________

RPM: ____________________

GPH: ________________________

GALLONS: _______________

After 20 seconds, the Instrument automatically goes into diagnostic mode. A minus sign (--) in the GALLONS window indicates
when this occurs. The Instrument remains in diagnostic mode until power is secured.

BLACK

RED

GREEN

16 15 14

11

9

10

12

13

1

2

3

4

5

6

7

8

LOWER BLACK SWITCH

0

0

0

BACK OF INSTRUMENT

0

BLACK

RED

GREEN

12

1

2

3

4

6

2

1

0

F

E

D

C

B

A

8

0

0

0

16 15 14 13

11 10 9

7

8

5

9

4

3

5

7

6

BACK OF INSTRUMENT