Electrical installation – Fire Magic Aurora Built-In Combo Grill A830i User Manual
Page 14

14
POWER SUPPLY HOOKUP
CAUTION: IMPROPERLY
CONNECTED
WIRES
WILL CAUSE DAMAGE TO THE GRILL 
AND MAY RESULT IN PROPERTY 
DAMAGE AND/OR PERSONAL INJURY.
This grill includes a power supply box. When installing 
the power supply box:
• It MUST be located at least 12 inches below the
bottom of the grill (see Fig. 14-3).
• The wire extension that exits from the control panel
MUST be routed directly downward. This will prevent 
overheating. DO NOT route the wire extension 
below the grill (see Fig. 14-3).
Note: For enclosures with a solid area beneath the
grill, a cutout must me made near the wire 
extension to allow for the above requirement. 
• DO
NOT block the vent holes found on the box.
Fasten the power supply box to the inside of the 
enclosure using appropriate hardware for your enclosure.
The electrical connections from the power supply box to 
the grill electrical systems come pre-connected. 
WARNING
Electrical Grounding Instructions
This outdoor-cooking gas appliance is equipped with a 
three-pronged (grounding) plug. Do not cut or remove 
the grounding prong from the plug.
CONNECT THE POWER SUPPLY TO LINE 
POWER
Plug the power supply cord into a properly wired 
and inspected GFCI electrical receptacle (15 AMP 
minimum). Use a heavy-duty grounded extension cord 
if necessary.
ELECTRICAL SAFETY
To protect against electric shock, do not immerse cord or plugs in water or other liquid;
Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts;
Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance malfunctions 
or has been damaged in any manner. Contact the manufacturer for repair;
Do not let the cord hang over the edge of a table or touch hot surfaces;
Do not use an outdoor cooking gas appliance for purposes other than intended;
When connecting, fi rst connect plug to the outdoor cooking gas appliance then plug appliance into the outlet;
Use only a Ground Fault Circuit Interrupter (GFCI) protected receptacle with this outdoor cooking gas appliance;
Never remove the grounding plug or use with an adapter of 2 prongs.
Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and approved 
for outdoor use with a W-A marking.
Grounded
plug
Required
GFI electrical
receptacle
(not included)
Grounded
plug
Required
GFCI electrical 
receptacle (not 
included)
12"
Min.
Fig. 14-3 Power supply clearance
Fig. 14-2 Wire connections
Fig. 14-1 Power supply detail
Route wires
directly downward
(to prevent
overheating)
ELECTRICAL INSTALLATION