INSTALLATION REQUIREMENTS

Installation must be performed by a qualifi ed professional
service technician.

This grill is designed for outdoor use only. DO NOT use this grill
inside a building, garage, enclosed area, or under any overhead
construction.

DO NOT use this grill in or on a recreational vehicle or boat.

Important: The grill is not insulated and is for installation

in non-combustible enclosures only. Refer to
the information below to ensure all required
clearances are met.

The grill must have a minimum clearance of 18" from
combustible materials/items
AT ALL TIMES.

Side and Rear Wall Clearances

For the minimum clearances between the grill and any side or rear
walls, your setup must fall within one (or more) of the following:

A. Clearance between grill and strictly non-combustible wall

(i.e. brick wall, see Fig. 10-1)

• The grill must have a minimum of 4" right, left, and rear

clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)

B. Clearance between grill and a protected combustible wall

(i.e. a non-combustible wall in front of a combustible wall to
serve as a barrier. This can be accomplished by brick, or
a metal stud fi nished with non-combustible substrate, see
Fig. 10-2)

• The grill must have a minimum of 14" right, left, and rear

clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional 10"
clearance between the grill and protected wall.)

C. Clearance between grill and combustible wall

• The grill must have a minimum of 18" right, left, and rear

clearance from any combustible wall (see Fig. 10-3).

Backsplash (if applicable)

If a non-combustible backsplash exists, it must have a minimum
of a 4" clearance from the rear of the grill (to allow for proper
ventilation and prevent dangerous overheating). See Fig. 10-4.

Important: This 4" backsplash clearance must fi rst be met prior

to any non-combustible walls beginning behind it.

Fig. 10-1 Clearance 'A' Diagram

Fig. 10-2 Clearance 'B' Diagram

Fig. 10-3 Clearance 'C' Diagram

Non-combustible

Min.

4"

(Clearance required for

right, left, and rear)

Min.

14"

Non-combustible

substrate

Non-combustible 4"

Combustible

Min.

18"

(Clearance required for

right, left, and rear)

(Clearance required for

right, left, and rear)

Fig. 10-4 Backsplash clearance

Non-combustible

Backsplash

Min.

4"

Com-

bustible