INSTALLATION REQUIREMENTS (cont.)

The control panel MUST remain removable for servicing
(see PARTS LIST).

THIS UNIT MUST NOT BE LOCATED IN A FULLY
ENCLOSED AREA OF ANY KIND.

ENSURE PROPER COMBUSTION AIR AND
COOLING AIRFLOW

Proper airfl ow (Fig. 11-1) MUST be maintained for the
grill to perform as it was designed. If airfl ow is blocked,
overheating and poor combustion will result. Do not
block the 1" (2.5 cm) front air inlet along the bottom
of the control panel or
more than 75% of the
cooking grid surface
with pans or griddles.

Note: The 1" (2.5 cm)

front air space
a l s o a l l o w s
access to the
drip tray.

GAS-SUPPLY PLUMBING REQUIREMENTS

For natural gas or a household propane system, rigid

1

/

2

"

(1.3 cm) or

3

/

4

" (1.9 cm) black steel pipe or local code-

approved pipe is required to conduct the gas supply to
the unit. Contact your local gas supplier. Connect this
pipe to the required C.S.A.-approved stainless-steel
fl ex connector (attached). An NPT adapter has been
provided for

1

/

2

" pipe. DO NOT use a rubber hose

within the grill enclosure. Apply only joint compounds
that are resistant to all gasses to all male pipe fi ttings
except fl are fi ttings. Make sure to tighten every joint
securely.

Note: If

1

/

2

" (1.3 cm) pipe is used with natural gas,

it should be no longer than 20' (6.1 meters).

Important:

An external valve (with a removable
key) in the gas line is necessary
for safety when the grill is not in
use. It also provides for convenient
maintenance.

Fig. 11-1

- Ventilation diagram

CAUTION: Wind blowing into or across the rear

oven lid vent (Fig. 11-2) can cause
poor performance and/or dangerous
overheating. Orient the grill so that the
prevailing wind blows toward the front of
the grill (Fig. 11-3).

Fig. 11-3

CORRECT

PLACE GRILL SO PREVAILING

WIND BLOWS TOWARD FRONT

OF GRILL

YOU MUST PROTECT

REAR OVEN VENT FROM

PREVAILING WIND

Rear oven lid vent

INCORRECT

Fig. 11-2

GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water column
(w.c.), minimum 5" (12.7 cm), maximum 10

1

/

2

" (26.7

cm). For propane gas - normal 11" w.c., minimum 10"
(25.4 cm), maximum 13" (33 cm).

REV 0 - 1412031335