Hi Voltage Indicator

In any VAC/VDC range, when you touch a voltage

greater than 30V, the beeper will beep and the red Hi-
V LED will blink. BE CAREFUL!

Capacitance

For motor-start and motor-run capacitors.

Disconnect the capacitor from power first. Short the
terminals to discharge the capacitor. Disconnect any
resistors that might be between the terminals of the
capacitor.

MAX and Data HOLD

Press MAX to store highest reading on the display.

Press MAX again to return display to real-time read-
ing. Press HOLD to hold current data on the display.

Silicone Leads

Because the wire insulation is silicone the leads

will stay flexible in cold weather and will not melt if
bumped by a soldering iron.

Safe One-Handed Testing

When testing electrical circuits with two hands,

there is a risk that a careless mis-
take may complete a circuit
through your body and potentially
cause death or injury.

First disconnect the top half of

red test lead and plug tip directly
into Volts jack. Plug alligator clip
lead into the COM jack (you may
need to use a lead with tip
removed as an extension). Then
clip the alligator lead to one test
point.

With the black alligator lead

secured, you’re now free to hold
the meter with one hand and
touch other test points with the
probe tip.

Modular Expandability

Modular expandability is the ability for accessory

heads and meters to change configurations to match
the various needs of an HVAC/R technician.

Accessory heads (the sensors) send a mV signal,

which represents the value of the parameter being
tested. Heads can attach directly to the top of a Stick
meter, DL3 data logger, or EHDL1. They can also
plug into any meter with mV ranges using ADLS2
leads.

Accessory Heads

Accessory heads, like the included ACH4, are the

sensors of multiple parameters measured by techni-
cians every day. They plug into a mV range (depend-
ing on the head) of a multimeter. The multimeter will
display whatever the head is measuring. Instead of
having to purchase and carry a separate instrument
for each parameter, a technician can use multiple
heads and a single multimeter to do the job.
Here are four of the many heads available:

AAV3

Air Velocity and Temperature

ADMN2 Dual-Port Manometer
AVG2 Digital Vacuum Gauge
AOX2

Combustion Check

HOLD

MAX

The Original Stick Meter

HS26

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

CAT.III 600V 200μA MAX

~

COM

V Ω

Works With Fieldpiece Accessory
Heads!

Connect to Fieldpiece accessory heads by simply

attaching them to the top of meter (1) or attach
remotely through leads (2). For most heads, move
dial to mVDC range shown (1). For the AAC clamp
(ACH4), move dial to VAC range (2).

HOLD

MAX

The Original Stick Meter

HS26

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

HOLD

MAX

The Original Stick Meter

HS26

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

CAT.III

300V
400A

CLAMP

ACH4

AC Current
Clamp

1AAC / 1mVAC
400AAC MAX

!

CAT.III 600V 200μA MAX

~

COM

V Ω

(1)

(2)

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

Voltage

Capacitance

Selecting Ranges

For DC voltage, set the meter to the VDC parame-

ter instead of VAC (shown below).

For all ranges choose a range just above the value

you expect. If display reads “OL” (overload), select a
higher range. If display shows less than three num-
bers, select a lower range for better resolution.

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

Diode Test

Resistance

Flame rectification

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600

Opman HS26 v214

CAT.III

300V
400A

CLAMP

ACH4

AC Current
Clamp

1AAC / 1mVAC
400AAC MAX

!

Air

Ve

lo

cit

y

&

Te

m

pe

ratu

re

He

ad

Englis

h

RE

AD

LO

BAT

T

ON

LC

D

X

100

Av

erage

(16

sec)

Metric

Real

time

AA

V3

AUT

O

-

OF

F

English

Metri

c

Ft/m

in

M/s

KM/h

r

MPH

ºF

ºC

OF

F

AO

X

2

Combusti

on

Chec

k

%

O

%

CO

T

EM

P

O

N

G

A

S

O

IL

L

o

B

att

°C

°F

AU

TO

O

FF

S

TA

B

LE

Fuel

Ty

pe

2

2

T/C

CAL

AUT

O-

OF

F

T/

C

Ca

l

ST

AB

LE

Pr

essu

re

Te

mp

SH

or

SC

ON

LO

BAT

T

R e

friger

a tion

Superhea

t

and

Subcooli

ng

EN

GL

IS

H

ME

TR

IC

R1

34

A

R4

04

A

Se

t

AT

M

AS

X2

4

SH

SC

Air Velocity

& Temperature

Head

English

READ

LO BATT

ON

LCD X

100

Average

(16 sec)

Metric

Real

time

AAV3

AUTO-

OFF

English

Metric

Ft/min

M/s

KM/hr

MPH

ºF

ºC

OFF

ADMN2

Dual-Port
Manometer
Accessory
Head

P1

P2

P1-P2

ON

0.1

ENGLISH

METRIC

0.01

(LCD/10)

Lo Batt

Resolution

ZERO

AUTO

OFF

P1

P2

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

AOX2

Combustion
Check

%

O

%

CO

TEMP

ON

GAS

OIL

Lo Batt

°C °F

AUTO

OFF

STABLE

Fuel Type

2

2

T/C

CAL

AAV3

ADMN2

AVG2

AOX2

Ω

V

DC

V

AC

MFD

µA

DC

2000m

2000m

200m

200m

200

200

200

200

200

600