beautypg.com

Fieldpiece AMN2 - Manometer Accessory Head User Manual

Page 2

background image

RMA316 Manometer Adapter

Used for 5/16" pressure outlet ports.

1. Shut off main gas supply to furnace.
2. Move the gas valve switch to "OFF" position.
3. Use a 3/32" hex wrench to loosen the outlet

pressure tap screw. Rotate screw counter-
clockwise one revolution to open.

4. Connect the AMN2 tubing to the smaller (3/16")

end of the adapter and the other (5/16") end of
the adapter into the of the adapter tube.

5. Slide the 5/16" adapter tube over the outlet

pressure boss (port) to seal. Overlap the pres-
sure boss by at least 3/8" to prevent leakage.

Outlet Pressure

Tap Screw

Outlet

Pressure

Boss

Inlet Pressure
Tap Screw

Smaller end (3/16”) of the adapter
connects to AMN2 tubing. Remove
the installed brass fitting from tube
so the adapter can be inserted.

Inlet Pressure
Boss

Adapter

(5/16” to 3/16”)

Adapter Tube

(5/16”)

More Products From Fieldpiece

Modular Expandability

Modular expandability is ability for accessory

heads and meters to change configurations to
match the various needs of an HVAC/R technician.

Accessory heads (the sensors) send out a mV

signal, which represents the value of the measure-
ment, to whatever meter is attached to it. Heads can
attach directly to the top of a Stick meter, DL3 data
logger, or EHDL1. They can also plug into any meter
with mV ranges using ASLS2 leads.

Stick Meter

This is the heart of modular expandability. In addi-

tion to being a full functioning multimeter, any acces-
sory head can be used with it.

Model HS36

Non contact voltage

Magnetic hanger

Autoranging

Backlight

Temperature

Volts, amps, ohms

Frequency

Microfarads

Includes:

HS36 Meter

ACH4 Current Clamp

ATB1 K-type TCouple

ADLS2 Deluxe Leads

ANC1 Case

Accessory Heads

Accessory heads are the sensors of multiple

parameters measured by technicians every day.
They plug into a mV range (depending on the head)
of a multimeter. The multimeter will display whatev-
er the head is measuring. Instead of having to pur-
chase and carry a separate instrument for each
parameter, a technician can use multiple heads and
a single multimeter to do the job.

Here are four of the many heads available:

AAV3 Air Velocity and Temperature
ADMN2 Dual-Port Manometer
AVG2 Digital Vacuum Gauge
AOX2 Combustion Check

CAT.III

300V
400A

CLAMP

ACH4

AC Current

Clamp

1AAC / 1mVAC
400AAC MAX

!

Air

Velocit

y

&

Temper

atur

e

Hea

d

En

glis

h

RE

AD

LO

BAT

T

ON

LC

D

X

100

Av

era

ge

(16

sec

)

M

etr

ic

Re

al

tim

e

AA

V3

AU

TO

-

O

FF

Eng

lish

Me

tric

Ft/m

in

M

/s

KM

/hr

M

PH

ºF

ºC

O

FF

A

O

X

2

Com

busti

on

Chec

k

%

O

%

C

O

T

E

M

P

O

N

G

A

S

O

IL

L

o

B

at

t

°C

°F

A

U

TO

O

F

F

S

TA

B

LE

F

u

el

T

y

p

e

2

2

T

/C

C

A

L

AU

TO

-

OF

F

T/

C

Ca

l

ST

AB

LE

Pr

ess

u

re

Te

mp

SH

or

SC

ON

LO

BA

TT

R efrig

er

a t

ion

Su

pe

rhe

a

t

and

Su

bco

oli

ng

ENG

LIS

H

ME

TR

IC

R13

4A

R4

04

A

Set

AT

M

AS

X24

SH

SC

Air Velocity

& Temperature

Head

English

READ

LO BATT

ON

LCD X

100

Average

(16 sec)

Metric

Real

time

AAV3

AUTO-

OFF

English

Metric

Ft/min

M/s

KM/hr

MPH

ºF

ºC

OFF

ADMN2

Dual-Port

Manometer

Accessory

Head

P1

P2

P1-P2

ON

0.1

ENGLISH

METRIC

0.01

(LCD/10)

Lo Batt

Resolution

ZERO

AUTO

OFF

P1

P2

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

AOX2

Combustion

Check

%

O

%

CO

TEMP

ON

GAS

OIL

Lo Batt

°C °F

AUTO

OFF

STABLE

Fuel Type

2

2

T/C

CAL