8.4 InstallatIon methoD of space Isolator
1) The Space Isolator is placed at the entrance to the stair or room generally.
2) You can place the Space Isolator at proper position to stop the Cleaner passing through
some places.
3) Remove obstacles from the area you want to block in front of the Space Isolator as much
as possible for fear of poor effect.
1) The Space Isolator should be placed at the same level of the ground where the Cleaner
is running.
2) You should check whether the Cleaner can pass the Space Isolator while using it first.
3) The distance between the Space Isolator and recharger should be more than 2.5 m, or there
will be interference.
4) The Docking Station should not be installed within the signal scope of the Space Isolator.
9. troUble shootInG
the cleaner doesn’t work or clean poorly
1) Check whether turning on the switch.
2) Check whether the dust box, filter and intake are clean, and whether the side brush works.
3) Check whether the battery voltage declines greatly.
the remote control doesn’t work
1) Check the battery status of the remote control.
2) Check the battery status of the Robot.
3) Check whether the remote control is within the available scope of the signal transmitting.
4) Turn the vacuum cleaner on/off with a mechanic switch on the main body.
the cleaner can not charge automatically
1) Check whether the adaptor is connected well with the charger and whether power LED
of the recharger lighting.
2) Check whether the battery power is too low if so charge the Cleaner with the adaptor
directly.
3) Make sure there is no barrier in front of the Docking Station.
4) Use the remote controller to let the cleaner go back to the Docking Station.
Increased noise in cleaning
1) Clean the dust box and filter.
2) Check whether the brush or side brush is too dirty.
3) If the noise still too big you may send back the cleaner to the after sale service
maintenance to add Lubricants.
the lcD shows „fUll“
1) Clean the dustbin, aligator brush in the inlet of dustbin and filter.
2) Clean with a dry cloth sensors to identify the level of floor pollution (O14).
the cleaner stops working suddenly and rings intermittently
1) Check whether the set cleaning time is over.
2) Check whether there are failure codes on the display by reference of the followings.