beautypg.com

Dynacord DPA 4260 User Manual

Page 18

background image

18

Installation Notes

Generally, it is important to install the power amplifier in a way, that ensures unhindered front-to-rear

air circulation.

When installing the power amplifier in a closed rack-shelf system, please make sure that adequate air-

flow is guaranteed. The space between the rear panel of the amplifier and the inner wall of the rack-

case has to be at least 60 mm x 330 mm. A free space of at least 100 mm above the rack-shelf system

is needed to provide sufficient air circulation. Since, during operation, the temperature inside the rack

system could easily rise up to 40° C, the maximum allowable ambient temperatures of the rest of the

incorporated modules and appliances within a specific rack-shelf system have to be taken into careful

consideration.

When mounting the power am-

plifier inside of a closed rack

system, it is recommended to

use special rack-rails or optio-

nally available rack-mount ears

NRS 90235 (112733) to prevent

bending of the appliance’s front

panel.

Note For maintained trouble-free operation of the appliance, the maximum admissible

ambient temperature of +40°C is not to be exceeded.

The amplifier has to be protected from:
- water drops or splashes
- direct sunlight
- high ambient temperatures and the direct radiation of heat sources
- high humidity and moisture - heavy dust
- massive vibrations

Moving the amplifier from a cold into a warm environment can result in the occurrence of condensation

on inner parts. Operating the appliance is only permissible after it has accommodated to the altered

temperature (approximately after one hour).Should any foreign solid parts or liquids inadvertently in-

trude the enclosure, immediately unplug the device from the power source and have it checked at a

DYNACORD service center, before further use.Cleaning the appliance should not be performed using

chemical solvents or sprays, as this might damage the finish and could even cause hazard fire.

Before The First Operation

Before switching the amplifier’s power on, the included mains cord has to be connected to a 230V

- 50/60 Hz wall outlet. On the appliance itself, the cord has to be connected to the 3-pole mains

socket.To remotely start the amplifier, it is necessary to connect an external 24 V power source to

the terminal strip POWER REMOTE. Providing correct connection and with an external power supply

being present, the POWER ON indicator will light and the power amplifier is ready for operation.The

mains switch POWER on the rear of the appliance is meant for service and maintenance purposes

only. Through bridging the mains switching relay this option provides the possibility to operate the am-

plifier without an external 24 V power supply connected.


Caution

The mains switch POWER on the rear of the appliance is only meant for

maintenance. Remotely switching off the device is not possible when the

POWER switch is engaged.

The DPA-Series power amplifiers employ power-on switching delays of approximately 2 seconds.