beautypg.com

DNF Controls USP-RDC User Manual

Page 11

background image

Page 11 of 13

Remote Follow GTP/DC – Tally Event Labels from GTP/DC

Extended Follow GTP/DC- Tally Extended Tally(ET) Event Labels from GTP/DC

Tally is ON when any of the assigned Event Labels is ON

The associated Event Label’s text and color entry is used

Tally is OFF when assigned Event Label is ON or all assigned Event Labels
are OFF

Follow GTP/DC User Register- Tally User Registers and their values from GTP/DC

Tally Main Err: Text and color displayed when Main remote device (Main Backup Pair) or

assigned remote device (not Main Backup Pair) goes offline

Backup Err: Color displayed when Backup remote device (Main Backup Pair) goes offline

Mismatch Err: For Main Backup Pair only. Color displayed when Main and Backup tally do

not match

OFF: (ET only) Text and color displayed when assigned OFF Event Label is received or all

assigned Event Labels are OFF

ET1, ET2, ET3, ET4: Text and color displayed when assigned Event Label is received

Tally Color Dark

Red

Green

Amber

Flashing Red

Blinking Red

Flashing Green

Blinking Green

Flashing Amber

Blinking Amber

Font Size Big: 1 row of 3 characters

Normal: 2 rows of 4 characters each

Small: 3 rows of 6 characters each

Event Label Manually enter, or cut & paste, the Event Label from the GTP-32’s or DC20’s Event

Notification Table. The event label is case sensitive, may not contain spaces, and must
exactly match the Event Notification Table entry. (Refer to the GTP-32 or DC20 User
Manual.)

Value For Follow GTP/DC User Register only. Enter User Register value to match.

NOTE- Redundant Mode of operation is enabled at powerup.

Use a USP key to turn Redundant Mode On/Off.