TALLY ASSIGNMENT Configuration Web Page


Use the Tally Assignment Table to assign a tally to a key. The Tally Assignment Table
contains one entry for each key. A key can tally OFF and up to 4 extended tally states
(OFF, ET1, ET2, ET3, ET4).

Key Number The USP keys number.

Tally Type Local- Tally local GPI, GPO, or key press

Remote- Tally status from Remote Device (GTP-32/DC20 Device Type)

Tally Source Local

Follow Key- Tally is ON when key is pressed

Tally is OFF when key is released

Redundant On- Tally is ON when Redundant Mode is on

Tally is OFF when Redundant Mode is off

Redundant Off- Tally is ON when Redundant Mode is off

Tally is OFF when Redundant Mode is on

Main Selected- Tally is ON when Redundant Mode is off and Main is selected

Tally is OFF when Redundant Mode is on or Backup is selected

Backup Selected- Tally is ON when Redundant Mode is off and Backup is selected

Tally is OFF when Redundant Mode is on or Main is selected