12. PRODUCTION SWITCHER PBIO TRIGGER VALUES
The Production Switcher outputs a Peripheral Bus trigger at specific Timeline key frames, as
programmed by the operator. The 2044CL performs a specific function for each trigger value:
GRASS VALLEY GROUP Production Switcher
Trigger
Value
Mode
0
Play (If OUT point is specified, stop at OUT.)
1
Recue to beginning of clip
2
Slo-mo using ST400 Preset Speed
3
Reverse Play
4
Still Frame
5
6
Record
7 or greater
Play
SONY Production Switcher
Trigger
Value
Mode
0
Recue to beginning of clip Play
1
Play (If OUT point is specified, stop at OUT.)
2
Slo-mo using ST400 Preset Speed
3 Reverse
Play
4 Still
Frame
5
6 Record
7 or greater
Play
To control more than one VTR, enable the Peripheral Device Address for each VTR. The Trigger
value will be sent to the enabled devices.