System installation – DNF Controls 4000CL-L Vs.3.0 User Manual
Page 5

5
4000CL-L, Vs.3.0, 400 Clip Fast Access System, Louth Protocol
3. SYSTEM
INSTALLATION
a.
Plug one end of a 9-conductor, RS422 serial cable into the VTR 1 (2, 3 or 4) connector
on the rear of the ST300. Plug the other end of the cable into the REMOTE connector on
the Video Server.
b.
Connect the supplied POWER SUPPLY, APX#4108, into the POWER connector on the
rear of the ST300. Plug the Power Supply into an outlet, 90 VAC – 240 VAC.
c.
Assign logical Louth ports to ST300’s VTR’s connectors.
1)
Press
[MENU].
2)
Turn the wheel until VTR Louth Address is displayed.
3)
Press
VTR[1], VTR[2], VTR[3] or VTR[4] to select VTR.
4)
Assign a Louth Port address by entering a style number 0-9 using the numeric
keypad. (0 turns that channel OFF.)
5)
The second line of the display will show “Input=Enter, Out=ESC.”
6)
Press
[ENTER] to select an Input Port.
(A “-“ will appear in front of the selected number.)
OR
[ESC] to select an Out Port.
7)
Repeat steps 3 - 6 above to assign Louth Address to ALL ST300 VTRs you
want to use.
8)
Press [ESC] to exit the MENU mode.
d.
Check SETUP MENU prior to using the ST300 to confirm proper Record mode and other
User settable modes.
Installation is complete.