No nc – Delta Dore 237 TYBOX Installation User Manual
Page 2
or
>10s
... ... ...
NO
NC
Thermostat input
Blue
Brown
Black
Gray
Installing the receiver
Replacing the batteries
1
3
4
2
1
31
1
12
0
23
0
59
2012 ...
EXIT
1
2
3
4
5
8
9
10
11
12
6
7
Time setting
1,5V - LR03/AAA
(Alkaline)
NO : Normally Open
NC : Normally Closed
Circulator control for the
boiler
Input control for boiler
thermostat
Mounting with screws
Attach to the wall using the screws
and plugs provided.
Mounting using double-sided adhesive
Before affixing the adhesive, make sure the
surface you are affixing it to is clean
The receiver must be positioned near the heating control (burner or thermostat input of the boiler).
So as not to disturb the radio transmission, the antenna must be positioned away from all metallic parts.
You can change the direction of operation of the relay
When there is an "on" command, the relay closes.
When there is an "off" command, the relay opens.
You can change the direction of operation of the relay
by pressing the corresponding button on the receiver
for 10 seconds.
Turn the selector dial to
.
The days flash.
Press + or - to select the day, then press OK
to confirm and move on to the next setting.
Repeat the process to set
the hours and minutes.
To exit the
"time setting" mode,
turn the selector dial.
You have approximately 30 seconds to change the
batteries before the time setting is reset
(if this happens, reprogramme the date and time).
When the batteries symbol appears. you have
approximately 1 month to change the batteries
(2 1.5 V LR03 or AAA alkaline batteries).